Contents Wiring diagrams Section: Automatic Air Conditioner All sections

Dye Injection Infiniti M45 II

Dye Injection

Note. (This procedure is only necessary when recharging the system or when the compressor has seized and was replaced.)

  1. Check A/C system static (at rest) pressure. Pressure must be at least 345 kPa (50 psi).
  2. Pour one bottle (1/4 ounce / 7.4 cc) of the A/C refrigerant dye into the injector tool (J-41459).
  3. Connect the injector tool to the A/C LOW PRESSURE side service fitting.
  4. Start engine and AUTO switch ON.
  5. When the A/C operating (compressor running), inject one bottle (1/4 ounce / 7.4 cc) of fluorescent dye through the low-pressure service valve using dye injector tool J-41459 (refer to the manufacture's operating instructions).
  6. With the engine still running, disconnect the injector tool from the service fitting.
  7. Operate the A/C system for a minimum of 20 minutes to mix the dye with the system oil. Depending on the leak size, operating conditions and location of the leak, it may take anywhere from minutes to days for the dye to penetrate a leak and become visible.