Home/Infiniti/J30/Infiniti J30 I (1992-1997)/Repair manual/Automatic HVAC System/A/c-Heater System - Automatic: Specifications
Contents Wiring diagrams Section: Automatic HVAC System All sections

A/c-Heater System - Automatic: Specifications Infiniti J30 I

A/C SYSTEM SPECIFICATIONS

ApplicationSpecification
Compressor TypeCalsonic V6 6-Cyl.
Compressor Belt Deflection (1)21/64-3/8" (8.5-9.5 mm)
System Oil Capacity(2) 8.5 ozs.
Refrigerant Capacity(3) 24.6-28.2 ozs.
System Operating Pressures (4)
High Side182-223 psi (12.8-15.7 kg/cm 2 )
Low Side23-28 psi (1.6-2.0 kg/cm 2 )
(1) With 22 lbs. (10 kg) applied midway on longest belt run (used belt specifications given). (2) Use Type "S" Oil (Part No. KLH00-PAGS0). (3) Use R-134a refrigerant. (4) With ambient temperature of 86°F (30°C) and engine speed of 1500 RPM. Let system operate for at least 10 minutes before checking.
(1)With 22 lbs. (10 kg) applied midway on longest belt run (used belt specifications given).
(2)Use Type "S" Oil (Part No. KLH00-PAGS0).
(3)Use R-134a refrigerant.
(4)With ambient temperature of 86°F (30°C) and engine speed of 1500 RPM. Let system operate for at least 10 minutes before checking.

MANUAL A/C SYSTEM SPECIFICATIONS

WARNINGTo avoid injury from accidental air bag deployment, read and carefully follow all SERVICE PRECAUTIONS and DISABLING & ACTIVATING AIR BAG SYSTEM procedures in appropriate AIR BAG RESTRAINT SYSTEM article in ACCESSORIES/SAFETY EQUIPMENT section.