Test Description
The numbers below refer to the step numbers on the diagnostic table.
- 1 This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
- 2 This step measures the performance of the A/C system.
- 3 This step is to allow for vehicle variations as well as high ambient air temperatures.
| Step | Action | Values | Yes | No |
| NOTE: The ambient air temperature must be at least 16°C (60°F). Do not induce additional air flow across the front of the vehicle during the test. If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test. |
| 1 | Park the vehicle inside or in the shade. Open the windows in order to ventilate the interior of the vehicle. If the A/C system was operating, allow the A/C system to equalize for about 2 minutes. Turn OFF the ignition. Install the J 43600 ACR 2000 Refrigerant Station. Record the ambient air temperature displayed on the J 43600 ACR 2000 Refrigerant Station.. Record the low and high side STATIC pressure readings. Are both the low and high side pressures within the specified value? | Above 16°C (60°F) 345 kPa (50 psi) Above 24°C (75°F) 483 kPa (70 psi) Above 33°C (90°F) 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing |
| 2 | NOTE: Record the relative humidity and the ambient air temperature at the time of the test. Close the vehicle doors and windows. Open the drivers door window 127-152 mm (5-6 inches). Select the following HVAC control settings: The A/C ON The coldest temperature setting The maximum blower speed The IP panel outlet mode All IP panel outlets are OPEN Recirculation mode Install the temperature probes to the J 43600 ACR 2000 Refrigerant Station. in the left and right center air outlets. Apply the parking brake. Place the transaxle/transmission in one of the following positions: PARK for Automatic NEUTRAL for Manual Start the engine. Operate the A/C system for 5 minutes. Inspect A/C components for the following conditions: Abnormal frost areas Unusual noises NOTE: Press the RESET button, before using the print function of the J 43600 ACR 2000 Refrigerant Station.. Print the following information: The panel outlet air temperatures The low-side pressure The high-side pressure Compare the low and high side pressures and the panel output temperatures to the table below. Does all the data recorded fall within the specified ranges of the table below? | | Go to Step 5 | Go to Step 3 |
| 3 | If the pressures and temperatures recorded do not fall within the specified ranges: Continue to operate the A/C system for an additional 5 minutes. RESET the J 43600 ACR 2000 Refrigerant Station. and record the pressures and temperatures again. Compare the low and high side pressures and the panel output temperature to the table below. Does all the data recorded fall within the specified ranges of the table below? | | Go to Step 5 | Go to Step 4 |
| 4 | Perform the necessary repairs. Refer to A/C Diagnostics Chart . Is the action complete? | | Go to Step 5 | |
| 5 | Operate the system in order to verify the test results. Did you find the same results? | | System OK | Go to Symptoms - HVAC Systems - Manual or Go to Symptoms - HVAC Systems - Automatic |
| NOTE |
| The ambient air temperature must be at least 16°C (60°F). Do not induce additional air flow across the front of the vehicle during the test. If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test. |
| NOTE |
| Record the relative humidity and the ambient air temperature at the time of the test. |
| NOTE |
| Press the RESET button, before using the print function of the J 43600 ACR 2000 Refrigerant Station.. |
Air Conditioning (A/C) System Performance Test (LV3)
| Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Discharge Air Temperature |
| Low Side | High Side |
| 13-18°C (55-65°F) | 0-100% | 158-268 kPa (23-39 psi) | 1281-1502 kPa (186-218 psi) | 14°C (57°F) |
| 19-24°C (66-75°F) | Below 40% | 192-316 kPa (28-46 psi) | 1371-1612 kPa (199-234 psi) | 18°C (63°F) |
| Above 40% | 231-372 kPa (31-54 psi) | 1391-1646 kPa (202-239 psi) | 20°C (68°F) |
| 25-29°C (76-85°F) | Below 35% | 248-365 kPa (36-53 psi) | 1502-1708 kPa (218-248 psi) | 20°C (68°F) |
| 35-50% | 268-392 kPa (39-57 psi) | 1522-1729 kPa (221-251 psi) | 22°C (70°F) |
| Above 50% | 289-447 kPa (42-65 psi) | 1543-1777 kPa (224-258 psi) | 24°C (75°F) |
| 30-35°C (86-95°F) | Below 30% | 289-413 kPa (42-60 psi) | 1612-1839 kPa (234-267 psi) | 23°C (73°F) |
| 30-50% | 316-461 kPa (46-67 psi) | 1632-1867 kPa (237-271 psi) | 27°C (79°F) |
| Above 50% | 351-537 kPa (51-78 psi) | 1646-1929 kPa (239-280 psi) | 30°C (86°F) |
| 36-41°C (96-105°F) | Below 20% | 323-440 kPa (47-64 psi) | 1722-1949 kPa (250-283 psi) | 24°C (75°F) |
| 20-40% | 351-509 kPa (51-74 psi) | 1743-1991 kPa (253-289 psi) | 28°C (82°F) |
| Above 40% | 399-571 kPa (58-83 psi) | 1777-2032 kPa (258-295 psi) | 33°C (90°F) |
| 42-46°C (106-115°F) | Below 20% | 372-489 kPa (54-71 psi) | 1853-2053 kPa (269-298 psi) | 28°C (81°F) |
| Above 20% | 399-564 kPa (58-82 psi) | 1867-2101 kPa (271-305 psi) | 33°C (90°F) |
| 47-49°C (116-120°F) | Below 30% | 447-571 kPa (65-83 psi) | 1970-2191 kPa (286-318 psi) | 33°C (90°F) |
A/C Performance Table - RPO LV3
The numbers below refer to the step numbers on the diagnostic table.
- 1 This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
- 2 This step measures the performance of the A/C system.
- 3 This step is to allow for vehicle variations as well as high ambient air temperatures.
| Step | Action | Values | Yes | No |
| NOTE: The ambient air temperature must be at least 16°C (60°F). Do not induce additional air flow across the front of the vehicle during the test. If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test. |
| 1 | Park the vehicle inside or in the shade. Open the windows in order to ventilate the interior of the vehicle. If the A/C system was operating, allow the A/C system to equalize for about 2 minutes. Turn OFF the ignition. Install the J 43600 ACR 2000 Refrigerant Station. Record the ambient air temperature displayed on the J 43600 ACR 2000 Refrigerant Station.. Record the low and high side STATIC pressure readings. Are both the low and high side pressures within the specified value? | Above 16°C (60°F) 345 kPa (50 psi) Above 24°C (75°F) 483 kPa (70 psi) Above 33°C (90°F) 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing |
| 2 | NOTE: Record the relative humidity and the ambient air temperature at the time of the test. Close the vehicle doors and windows. Open the drivers door window 127-152 mm (5-6 inches). Select the following HVAC control settings: The A/C ON The coldest temperature setting The maximum blower speed The IP panel outlet mode All IP panel outlets are OPEN Recirculation mode Install the temperature probes to the J 43600 ACR 2000 Refrigerant Station. in the left and right center air outlets. Apply the parking brake. Place the transaxle/transmission in one of the following positions: PARK for Automatic NEUTRAL for Manual Start the engine. Operate the A/C system for 5 minutes. Inspect A/C components for the following conditions: Abnormal frost areas Unusual noises NOTE: Press the RESET button, before using the print function of the J 43600 ACR 2000 Refrigerant Station.. Print the following information: The panel outlet air temperatures The low-side pressure The high-side pressure Compare the low and high side pressures and the panel output temperatures to the table below. Does all the data recorded fall within the specified ranges of the table below? | | Go to Step 5 | Go to Step 3 |
| 3 | If the pressures and temperatures recorded do not fall within the specified ranges: Continue to operate the A/C system for an additional 5 minutes. RESET the J 43600 ACR 2000 Refrigerant Station. and record the pressures and temperatures again. Compare the low and high side pressures and the panel output temperature to the table below. Does all the data recorded fall within the specified ranges of the table below? | | Go to Step 5 | Go to Step 4 |
| 4 | Perform the necessary repairs. Refer to A/C Diagnostics Chart . Is the action complete? | | Go to Step 5 | |
| 5 | Operate the system in order to verify the test results. Did you find the same results? | | System OK | Go to Symptoms - HVAC Systems - Manual or Go to Symptoms - HVAC Systems - Automatic |
| NOTE |
| The ambient air temperature must be at least 16°C (60°F). Do not induce additional air flow across the front of the vehicle during the test. If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test. |
| NOTE |
| Record the relative humidity and the ambient air temperature at the time of the test. |
| NOTE |
| Press the RESET button, before using the print function of the J 43600 ACR 2000 Refrigerant Station.. |
Air Conditioning (A/C) System Performance Test (L83)
| Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Discharge Air Temperature |
| Low Side | High Side |
| 13-18°C (55-65°F) | 0-100% | 248-282 kPa (36-41 psi) | 1191-1378 kPa (173-200 psi) | 13°C (55°F) |
| 19-24°C (66-75°F) | Below 40% | 310-365 kPa (45-53 psi) | 1357-1570 kPa (197-228 psi) | 20°C (68°F) |
| Above 40% | 282-365 kPa (41-53 psi) | 1329-1598 kPa (193-232 psi) | 20°C (68°F) |
| 25-29°C (76-85°F) | Below 35% | 330-399 kPa (48-58 psi) | 1481-1701 kPa (215-247 psi) | 23°C (73°F) |
| 35-50% | 330-406 kPa (48-59 psi) | 1488-1728 kPa (216-251 psi) | 24°C (75°F) |
| Above 50% | 323-420 kPa (47-61 psi) | 1502-1777 kPa (218-258 psi) | 27°C (79°F) |
| 30-35°C (86-95°F) | Below 30% | 351-434 kPa (51-63 psi) | 1591-1839 kPa (231-267 psi) | 27°C (79°F) |
| 30-50% | 358-454 kPa (52-66 psi) | 1612-1908 kPa (234-277 psi) | 29°C (84°F) |
| Above 50% | 365-489 kPa (53-71 psi) | 1646-1998 kPa (239-290 psi) | 33°C (91°F) |
| 36-41°C (96-105°F) | Below 20% | 372-454 kPa (54-66 psi) | 1701-1949 kPa (247-283 psi) | 28°C (81°F) |
| 20-40% | 385-489 kPa (56-71 psi) | 1729-2039 kPa (251-296 psi) | 32°C (88°F) |
| Above 40% | 406-523 kPa (59-76 psi) | 1791-2129 kPa (260-309 psi) | 37°C (97°F) |
| 42-46°C (106-115°F) | Below 20% | 392-475 kPa (57-69 psi) | 1818-2060 kPa (264-299 psi) | 29°C (84°F) |
| Above 20% | 413-523 kPa (60-76 psi) | 1867-2177 kPa (271-316 psi) | 34°C (93°F) |
| 47-49°C (116-120°F) | Below 30% | 434-530 kPa (63-77 psi) | 1977-2239 kPa (287-325 psi) | 34°C (93°F) |
A/C Performance Table - RPO L83