GENERAL SPECIFICATIONS

ItemSpecification
A/C Compressor
TypeVisteon FS-10 swashplate, 5 double-acting pistons
Displacement170 cc (10.4 cu in)
RotationClockwise
A/C Pressure Relief Valve (1)
Open pressures3,792-4,137 kPa (550-600 psi)
Coolant Hose Lubricant
MERPOL®ESE-M99B144-B
Evaporator Core Orifice
ColorOrange
Diameter1.45 mm (0.057 in)
Magnetic Clutch
Air gap clearance0.35-0.75 mm (0.014-0.030 in)
Dual Function Pressure Switch (1)
Fan on/open2,137-2,344 kPa (310-340 psi)
Fan off/close1,655-2,137 kPa (240-310 psi)
Clutch off/open2,999-3,275 kPa (435-475 psi)
Clutch on/close1,517-1,931 kPa (220-280 psi)
Low Charge Switch
Open pressure69 kPa (10 psi)
Close pressure138 kPa (20 psi)
Evaporator Discharge Temperature Sensor
On temperature4°C (39°F)
Off temperature3°C (37°F)
Refrigerant Lubricant and Capacity
PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C)WSH-M1C231-B
Capacity195 ml (6.6 oz)
Refrigerant and Capacity
R-134a Refrigerant YN-19WSH-M17B19-A
Capacity0.96 kg (34 oz)
Refrigerant System Cleaner
A/C Systems Flushing Solvent F4AZ-19579-A
(1) Manifold gauge set pressures may vary slightly depending on the distance between the service gauge port valve and the A/C pressure relief valve, the A/C cycling switch, or the pressure cutoff switch location.
(1)Manifold gauge set pressures may vary slightly depending on the distance between the service gauge port valve and the A/C pressure relief valve, the A/C cycling switch, or the pressure cutoff switch location.