Contents Section: A/c Compressor All sections

HVAC System - Air Conditioning: Specifications Ford Taurus IV рестайлинг

A/c Compressor ~180 words

GENERAL SPECIFICATIONS

ItemSpecification
Magnetic Clutch
Air gap between pulley and clutch plate0.35-0.75 mm (0.014-0.030 in)
Lubricant
PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C)WSH-M1C231-B
O-ring/Seal Lubricant
Refrigerant Compressor Oil (Mineral Oil) F73Z-19577-AA (Motorcraft YN-9-A)ESH-M2C31-A2

GENERAL SPECIFICATIONS

TORQUE SPECIFICATIONS

DescriptionNm
Low-pressure service gauge port valve cap0.8
High-pressure service gauge port valve cap0.8
Low-pressure Schrader-type valve1.8
High-pressure Schrader-type valve2.5
Compressor manifold and tube assembly mounting bolt20
A/C compressor mounting bolts25
A/C compressor bracket support bolts25
A/C compressor clutch disc and hub bolt13
Evaporator core orifice connection24
Roll restrictor bracket bolts - 3.0L (2V)25
Condenser core mounting bolts6
A/C (peanut) fitting nuts8
Power steering pump pressure line fitting37
Condenser-to-evaporator line bracket bolts9
Fuel line bracket bolts8

TORQUE SPECIFICATIONS

The A/C refrigerant system is a clutch cycling orifice tube type. The system components include

  1. A/C compressor (19703)
  2. A/C clutch assembly
  3. A/C condenser core (19712)
  4. A/C evaporator core (19860)
  5. A/C suction accumulator (19C836)
  6. connecting refrigerant lines

The refrigeration system operation is controlled by the

  1. A/C evaporator core orifice (19D990)
  2. evaporator air discharge temperature sensor (19C734)
  3. A/C compressor pressure relief valve (19D644)
  4. dual function pressure switch (19D594)
  5. low charge protection switch (19E561)

The refrigerant system incorporates an A/C compressor controlled by an evaporator air discharge temperature sensor.

The evaporator air discharge temperature sensor senses the A/C evaporator core temperature to control A/C compressor operation. For additional information concerning the evaporator air discharge temperature sensor, refer to CONTROL COMPONENTS .

An A/C pressure relief valve is installed in the A/C manifold and tube (19D734) to protect the refrigerant system against excessively high refrigerant pressures.

The A/C evaporator core orifice is installed in the condenser to evaporator tube (19835) to meter the liquid refrigerant into the A/C evaporator core.