Contents Section: Cooling System (Mechanical) All sections

Engine Cooling - (Hybrid): Overview Ford Escape I рестайлинг

Normal Operation

Under normal operation in low speed, the LH fan only is in operation. Voltage is supplied to the low speed cooling fan relay through circuit 1822 (LB). When the relay is energized, voltage is fed to the LH cooling fan motor through circuit 538 (GY/RD). Ground for the cooling fan motor is provided through circuit 57 (BK).

Under normal operation in medium speed, both fans are in operation. Voltage is supplied to the medium speed cooling fan relay through circuit 1823 (YE/BK). When the relay is energized, voltage is fed to the RH cooling fan resister through circuit 3829 (LB/BK), then to the RH cooling fan motor through circuit 229 (RD/OG). Ground for the cooling fan motor is provided through circuit 57 (BK).

Under normal operation in high speed, both fans are in operation. Voltage is supplied to the high speed cooling fan relay through circuit 1823 (YE/BK). When the relay is energized, voltage is fed to the RH cooling fan motor through circuit 229 (RD/OG), bypassing the RH cooling fan resister. Ground for the cooling fan motor is provided through circuit 57 (BK).