Home/Citroen/Jumper/Citroen Jumper II (2006-2012)/Repair manual/Power unit/Description - function: air flow meter
Contents Wiring diagrams Section: Power unit All sections

Description - function: air flow meter Citroen Jumper II

Power unit ~393 words

Description

(1) air flow meter

"a" 4-way black connector

Supplier: BOSCH

Role

Role of the air flowmeter

  • To measure the quantity of air admitted into the engine
  • To measure the temperature of the air admitted

Function

Inlet air flow

(1) air flow meter

"A" clean air

"B" air containing impurities

"b" clean air measuring channel

"c" main air outlet

"d" detection cell

"e" clean air measuring channel outlet

"f" main air inlet

The body of the sensor has a bypass duct to ensure that the signal is not disturbed by any impurities contained in the air or by corrosion

The main flow of air enters the body of the sensor at "f" and the impurities contained in the admitted air, being heavier than the clean air, are evacuated via the principal outlet "c"

The flow of air traverses the measuring channel and acts on a detection cell "d" that has a thin heated membrane

The hot film membrane is maintained at a constant temperature (approximately 120° higher than the temperature of the air at the inlet) by a heating resistor

The flow of air that passes through the measuring channel tends to draw heat from the membrane and consequently, to maintain this latter at a constant temperature, a certain current must pass through the resistor

This current proportional to the flow of air is measured by the integral electronic stage which delivers a variable frequency signal that is a function of the flow of air at the inlet

Intake air temperature

(1) air flow meter

"g" air temperature sensor

The inlet air temperature sensor is a negative temperature coefficient (NTC) sensor

The NTC (Negative Temperature Coefficient) resistance value changes in relation to the change in the temperature

  • When the temperature increases, the resistance value decreases
  • When the temperature decreases, the resistance value increases

The value of the CTN (negative temperature coefficient) resistance is processed by the electronic stage of the air flowmeter

The electronic stage of the air flowmeter delivers an open cycle ratio output signal (RCO)

Electrical features

designationminimal valuemaximal value
operating temperature-40 °C120 °C
operating temperature (for a maximum duration of 3 minutes)-130 °C
supply voltage7,5 V17 V
supply current0,06A0,1A
frequency of the signal for the flow of air at the inlet1,5 kHz12 kHz
error in measuring the flow of air at the inlet2%5%

Inlet air flow

The frequency of the output signal varies as a function of the flow of air measured

"F" nominal frequency (Hz)

"G" air flow (Kg/h)

air flownominal frequency
10 Kg/h2012 Hz
40 Kg/h2507 Hz
105 Kg/h3204 Hz
220 Kg/h4308 Hz
480 Kg/h7759 Hz
620 Kg/h11130 Hz

Intake air temperature

"H" nominal resistance (ohms)

"J" air temperature (°C)

nominal resistanceair temperature
40000 ohms-40 °C
30000 ohms-34 °C
20000 ohms-25 °C
10000 ohms-12 °C
5000 ohms4 °C
4000 ohms8 °C
3000 ohms14 °C
2000 ohms23 °C
1000 ohms40 °C
652 ohms60 °C
0 ohms130 °C

Connector

number of channelsallocation of channels of connector
1supply voltage (12V)
2earth
3air temperature signal
4air flow signal

Programming/initialisation

Programming is necessary if the part is removed/refitted