When Monitored and Set Condition
- When Monitored: Always monitored with system active at each ignition cycle.
- Set Condition: If the SLA detects a short to ground on the Reverse Lamp Supply circuit.
| Possible Causes |
|---|
| REVERSE LAMP SUPPLY CIRCUIT SHORT TO GROUND |
| SHIFT LEVER ASSEMBLY |
For a complete Shift Lever Assembly Circuit Diagram, see SCHEMATICS AND DIAGRAMS .
Scheme 272
- 1) TEST REVERSE LAMP SUPPLY CIRCUIT SHORT TO GROUND Turn the ignition off. Disconnect the Shift Lever Assembly harness connector. NOTE: Check connector - Clean/repair as necessary. Measure the resistance between ground and the Reverse Lamp Supply circuit. Is the resistance above 100k ohms? Yes Replace the Shift Lever Assembly. Refer to «REMOVAL»(/chrysler/crossfire/i-final-2008-2008/remont/automatic-trans/#nag1-automatic-transmission-service-information) . No Repair the Reverse Lamp Supply circuit for a short to ground. Perform «NAG1 TRANSMISSION VERIFICATION TEST»(/chrysler/crossfire/i-final-2008-2008/remont/automatic-trans/#nag1-automatic-transmission-electrical-diagnostics__nag1-transmission-verification-test) .