BELT ADJUSTMENT
Open vent plug next to right side of expansion tank cap. Turn ignition on. Place heater control in maximum temperature position. Set blower motor to low setting. Fill expansion tank with coolant until no bubbles appear at vent plug. Close vent plug. Fill coolant until it reaches maximum cold fill level. Start and run engine and continue to add coolant to expansion tank as coolant level drops, until coolant is free of air bubbles. Check for leaks.
Scheme 1
COOLING SYSTEM SPECIFICATIONS
| Application | Quantity | |
|---|---|---|
| Cooling System (1) | ||
| All Models | 8.4 Qts. (7.9L) | |
| (1) Quantity is approximate. | ||
| (1) | Quantity is approximate. |
COOLANT CAPACITY