Contents Wiring diagrams Section: Automatic HVAC System All sections

Automatic A/c-Heater Systems BMW M3 E46

SPECIFICATIONS

ApplicationSpecification
Compressor TypeNippondenso Or Seiko-Seiki
Refrigerant (R-134a) Capacity
Round Tube Condenser35.2 ozs.
Flat Tube Condenser29.0 ozs

SPECIFICATIONS (E36/7 Z3)

ApplicationSpecification
Refrigerant (R-134a) Capacity26.0 ozs

SPECIFICATIONS (E46)

DESCRIPTION

WARNINGTo avoid injury from accidental air bag deployment, read and carefully follow all SERVICE PRECAUTIONS and DISABLING & ACTIVATING AIR BAG SYSTEM procedures in AIR BAG SYSTEM SAFETY article under GENERAL SERVICING.

REMOVAL & INSTALLATION

WARNINGTo avoid injury from accidental air bag deployment, read and carefully follow all SERVICE PRECAUTIONS and DISABLING & ACTIVATING AIR BAG SYSTEM procedures in AIR BAG SYSTEM SAFETY article in GENERAL SERVICING.

Note. Removal and installation procedures were not available from manufacturer at time of publication.

TORQUE SPECIFICATIONS

ApplicationFt. Lbs. (N.m)
Compressor Filler Plug22 (30)
Pipe Connections
5/8"15 (20)
3/4"29 (39)
7/8"31 (42)
11/16"35 (48)
Pressure Safety Switch
High Pressure(1) 18 (25)
Low Pressure(1) 14 (19)
Pressure & Suction Lines To Compressor15 (20)
(1) Apply locking compound to threads.
(1)Apply locking compound to threads.

TORQUE SPECIFICATIONS

WIRING DIAGRAMS