Fuel consumption display, adapting
| Rapid data transfer HELP Select function XX |
Indicated on display
- Press buttons -1- and -0- and confirm input with Q button.
| Adaptation Enter channel number XX |
Indicated on display
- Press buttons -0- and -3- to access "channel 03".
- Press -Q- button to confirm input
Note. Adaptation is only possible on vehicles with on-board computer. The value entered must be between 85% and 115%. The value must be entered in steps of 5%. If the value "100" was changed due to a customer complaint, the changed value must be entered into a new instrument cluster.
| Channel 3 Adaptation 100 --> < - 1 3- > |
Indicated on display
- Press --> button.
Note. The fuel consumption display can only be adapted via direct input.
| Channel 3 Adaptation 100 Enter adaptation value XXXXX |
Indicated on display
- Enter required adaptation value via button pad on scan tool, filling in the initial spaces with "0."
Example
- Required value: 90%
- Entry via button pad: 00090
| Channel 3 Adaptation 100 Q Enter adaptation value 00090 |
Indicated on display (example only)
- Press -Q- button to confirm input
| Channel 3 Adaptation 90 Q Store changed value? |
Indicated on display
- Press -Q- button to confirm input
| Channel 3 Adaptation 90 --> Changed value is stored |
Indicated on display
- Press --> button to terminate adaptation of fuel consumption display.
| Rapid data transfer HELP Select function XX |
Indicated on display
- Press buttons -1- and -0- and confirm input with Q button.
Note. If an incorrect entry is made the testing unit will switch to function mode.
| Function is unknown or --> cannot be carried out at the moment |
Indicated on display
- Press " button.
- Select adaptation function (function 10) and adaptation channel 03 again.
- Repeat adaptation of fuel consumption display and confirm entry with -Q- button.