Checking internal resistance
- Connect hand multimeter V.A.G 1526C for resistance measurement as follows.
| Leak detection pump (LDP) Terminal | Specified value |
|---|---|
| 1 - + - 3 | 640 to 720 ohms |
| 2 - + - 3 | 15 to 17 ohms |
If specifications are not obtained
- Replace Leak Detection Pump (LDP) V144 --> «Leak Detection Pump (LDP) V144 , removing and installing»(/audi/s6/c6-2006-2008/remont/fuel-system/#fuel-supply-system__leak-detection-pump-ldp-v144) .
If specified values are achieved
- Check voltage supply of leak detection pump «Checking voltage supply»(/audi/s6/c6-2006-2008/remont/fuel-system/#fuel-supply-system) .