Notes for installation

  1. After installing, always carry out On Board Diagnostic (OBD) of air conditioning system. See «ON BOARD DIAGNOSTIC (OBD), INITIATING»(/audi/a6/c5-1997-2001/remont/heated-glassdefoggers/#on-board-diagnostic-obd-hvac) .
  2. When installing the positioning motor, make sure that the actuator arm is properly engaged.
  3. Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm on the positioning motor).

Scheme 48

Scheme 48: Actuator for temperature flap left -V158-, removing and installing

Scheme 49

Scheme 49
  1. Remove storage compartment on driver's side. See «DRIVER'S STORAGE COMPARTMENT, REMOVING»(/audi/a6/c5-1997-2001/remont/mirrors/#interior-equipment__drivers-storage-compartment-removing).
  2. Remove entire center section of instrument panel and also reinforcement bracket. See «INSTRUMENT PANEL»(/audi/a6/c5-1997-2001/remont/exteriorinterior-trim/#interior-trim).
  3. Remove left hand instrument panel support by unscrewing bolt -A-, bolts -B- (2x) and bolts -C- (2x). (Scheme 54)
  4. Remove wiring harness -D- from left instrument panel support.
  5. Disconnect harness connector -A-. (Scheme 55)
  6. Remove 3 bolts -B-.
  7. Carefully disengage coupling rod -C- using screwdriver -D- and remove positioning motor.