Contents Wiring diagrams Section: Engine Controls - on Board Diagnostic (OBD) - 3.0l Avk All sections

A - Changing adaptation value using scroll bar Audi A4 B6

A - Changing adaptation value using scroll bar

Display on VAS5051

Scheme 125

Scheme 125: A - Changing adaptation value using scroll bar
  1. Move scroll bar -5- in desired direction or click on area next to scroll bar, which will move it in desired direction.
  2. Press "Save" button -4-.
Engine speed increase
Adaptation value001290013000131001320013300134
Engine speed in steps+10 rpm+20 rpm+30 rpm+40 rpm+50 rpm+60 rpm
Engine speed decrease
Adaptation value0012700126001250012400123001220012100120
Engine speed in steps10 rpm20 rpm30 rpm40 rpm50 rpm60 rpm70 rpm80 rpm

ENGINE SPEED ADAPTION VALUES: USING SCROOL BAR

Display on VAS5051

Scheme 126

Scheme 126
  1. 1 - Save channel X
  2. 2 - Display text of selected channel or No display
  3. 4 - Original value X New value X
  1. Confirm new adaptation value by pressing "Accept" button -3-.

Display on VAS5051

Scheme 127

Scheme 127
  1. Channel X Value X stored Exit function "10 - Adaptation" by pressing <= button. NOTE: An engine speed decrease follows immediately, an increase in engine speed is only effective after briefly pressing the accelerator pedal.