DECOUPLING STABILIZER BAR, BLEEDING
Special tools and workshop equipment required
- Transparent plastic tube, inner diameter 6 mm, approximately 1 meter in length
Depressurize hydraulic system using Vehicle diagnostic tester.
Check oil level in engine pump assembly, refer to DECOUPLING STABILIZER BAR HYDRAULIC SYSTEM, CHECKING OIL LEVEL AND FILLING .
Connect hose to bleeder nipple -arrows-.
Scheme 58
Secure hose on bleeder nipples using cable ties or hose clamp.
Note. Without this securing measure, hose would slide from bleeder nipples during bleeding because of high pressure.
Loosen bleeder nipple by approximately 1 turn.
Follow instructions on Vehicle diagnostic tester.
Tighten bleeder nipple and remove hose.
Check oil level in engine pump assembly again, refer to DECOUPLING STABILIZER BAR HYDRAULIC SYSTEM, CHECKING OIL LEVEL AND FILLING .