Contents Wiring diagrams Section: Front Suspension All sections

DECOUPLING STABILIZER BAR, BLEEDING Volkswagen Touareg I

Front Suspension 1 illustration ~129 words

DECOUPLING STABILIZER BAR, BLEEDING

Special tools and workshop equipment required

  1. Transparent plastic tube, inner diameter 6 mm, approximately 1 meter in length

Depressurize hydraulic system using Vehicle diagnostic tester.

Check oil level in engine pump assembly, refer to DECOUPLING STABILIZER BAR HYDRAULIC SYSTEM, CHECKING OIL LEVEL AND FILLING .

Connect hose to bleeder nipple -arrows-.

Scheme 58

Scheme 58

Secure hose on bleeder nipples using cable ties or hose clamp.

Note. Without this securing measure, hose would slide from bleeder nipples during bleeding because of high pressure.

Loosen bleeder nipple by approximately 1 turn.

Follow instructions on Vehicle diagnostic tester.

Tighten bleeder nipple and remove hose.

Check oil level in engine pump assembly again, refer to DECOUPLING STABILIZER BAR HYDRAULIC SYSTEM, CHECKING OIL LEVEL AND FILLING .