Contents Section: Starter All sections

Starting System -- Specifications: Other Toyota Avalon XX20 рестайлинг

SERVICE DATA

StarterRated voltage and output power12 V 1.4 kW
No-load characteristicsCurrent90 A or less at 11.5 V
Rpm3,000 rpm or more
Brush lengthSTD15.5 mm (0.610 in.)
Minimum10 mm (0.394 in.)
Spring installed loadSTD17.6 - 23.5 N (1.79 - 2.41 kgf, 4.0 - 5.3 lbf)
Minimum11.8 N (1.20 kgf, 2.7 lbf)
Commutator
DiameterSTD30.0 mm (1.181 in.)
Minimum29.0 mm (1.142 in.)
Undercut depthSTD0.6 mm (0.024 in.)
Minimum0.2 mm (0.008 in.)
Circle runoutMaximum0.05 mm (0.0020 in.)
Magnetic switch
Contact plate for wearMaximum0.9 mm (0.035 in.)

Starting Service Data