Contents Wiring diagrams Section: Automatic HVAC System All sections

Air Conditioning System: NVH Suzuki Aerio I

Abnormal Noise from Compressor

ConditionPossible CauseAction
Compressor: During compressor operation, a rumbling noise is heard proportional to engine revolutions .Inadequate clearance in piston area (piston or swash-plate)Repair or replace compressor as necessary .
Compressor: A loud noise is heard at a certain rpm, disproportionately to engine revolution .Loose or faulty compressor drive beltReplace drive belt.
Loose compressor mounting boltsRetighten mounting bolts.
Compressor: A loud rattle is heard at low engine rpm .Loose compressor clutch plate boltRetighten clutch plate bolt. Replace compressor if it was operated in this condition for a long time .

A/C SYSTEM PROBLEM SYMPTOMS DIAGNOSTIC CHART (ABNORMAL NOISE FROM COMPRESSOR)

Abnormal Noise from Magnetic Clutch

ConditionPossible CauseAction
Magnet Clutch: A rumbling noise is heard when compressor is not operating .Worn or damaged bearingsReplace magnet clutch assembly .
Magnet Clutch: A chattering noise is heard when compressor is engaged .Faulty clutch clearance (excessive)Adjust clutch clearance .
Worn clutch friction surfaceReplace magnet clutch assembly .
Compressor oil leaked from shaft seal, contaminating the friction surfaceReplace compressor body assembly .

A/C SYSTEM PROBLEM SYMPTOMS DIAGNOSTIC CHART (ABNORMAL NOISE FROM MAGNETIC CLUTCH)

Abnormal Noise from Tubing

ConditionPossible CauseAction
Tubing: A droning noise is heard inside vehicle, but not particularly noticeable in engine compartment .Faulty tubing clampsReposition clamps or increase the number of clamps .
Resonance caused by pulsation from variations in refrigerant pressureAttach a silencer to tubing, or modify its position and length .

A/C SYSTEM PROBLEM SYMPTOMS DIAGNOSTIC CHART (ABNORMAL NOISE FROM TUBING)

Abnormal Noise from Condenser

ConditionPossible CauseAction
Condenser: Considerable vibration in condenser .Resonance from condenser bracket and bodyFirmly insert a silencer between condenser bracket and body .

A/C SYSTEM PROBLEM SYMPTOMS DIAGNOSTIC CHART (ABNORMAL NOISE FROM CONDENSER)

Abnormal Noise from Crankshaft Pulley

ConditionPossible CauseAction
Crankshaft Pulley: A large rattling noise is heard at idle or sudden acceleration .Loosen crankshaft pulley boltRetighten bolt .

A/C SYSTEM PROBLEM SYMPTOMS DIAGNOSTIC CHART (ABNORMAL NOISE FROM CRANKSHAFT PULLEY)

Abnormal Noise from Tensioner Pulley

ConditionPossible CauseAction
Tensioner Pulley: Clattering noise is heard from pulley .Worn or damaged bearingReplace tensioner pulley .
Tensioner Pulley: Pulley cranks upon contact .Cracked or loose bracketReplace or retighten bracket .

A/C SYSTEM PROBLEM SYMPTOMS DIAGNOSTIC CHART (ABNORMAL NOISE FROM TENSIONER PULLEY)

Abnormal Noise from A/C Evaporator

ConditionPossible CauseAction
A/C Evaporator: Whistling sound is heard from A/C evaporator .Depending on the combination of the interior / exterior temperatures, engine rpm and refrigerant pressure, the refrigerant flowing out of the expansion valve may, under certain conditions, make a whistling soundAt times, slightly decreasing refrigerant volume may stop this noise. Inspect expansion valve and replace if faulty .

A/C SYSTEM PROBLEM SYMPTOMS DIAGNOSTIC CHART (ABNORMAL NOISE FROM A/C EVAPORATOR)