Drain Valve
See FUEL EVAPORATIVE SYSTEM under EMISSION SYSTEMS.
Drain Filter
The drain filter is installed at the air inlet port of the vent control solenoid valve. It cleans the air taken in the canister through the vent control solenoid valve.
Scheme 1