Contents Section: Body Electrical All sections

Accessory Power Socket: Other Pontiac Vibe I рестайлинг

Intermittent

Faulty electrical connections or wiring may be the cause of intermittent conditions. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.

Power Outlet Receptacle Inoperative

StepActionYesNo
Schematic Reference: Cigar Lighter/Auxiliary Outlets Schematics DEFINITION: This table diagnoses the 115 volt outlet inoperative.
1Turn ON the ignition with the Engine off. Press the 115 volt Power Outlet Switch to the on position and release. Did the 115 volt power outlet lamp illuminate?Go to Step 2Go to Step 3
2With the ignition ON and the power outlet switch on: Test the 115 volt Power Outlet for AC voltage. Did you measure 115 volts AC?Go to Testing for Intermittent Conditions and Poor Connections in Wiring SystemsGo to Step 5
3With the ignition ON and the power outlet switch on: Connect a test lamp between the feed circuit at the 115 volt power outlet switch and ground. Did the test lamp illuminate?Go to Step 4Go to Step 16
4Test the ground circuit of the 115 volt power outlet switch for continuity. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition?Go to Step 24Go to Step 13
5With the ignition ON and the power outlet switch on: Connect a test lamp between the INV relay coil feed circuit at the 115 volt power outlet switch and ground. Did the test lamp illuminate?Go to Step 6Go to Step 13
6With the ignition ON and the power outlet switch on: Connect a test lamp between the accessory AC/DC power control module supply voltage at the module and ground. Did the test lamp illuminate?Go to Step 7Go to Step 9
7Test the ground circuit of the accessory AC/DC power control module for continuity. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition?Go to Step 24Go to Step 8
8With the ignition ON and the power outlet switch on: Test the output of the accessory AC/DC power control module for AC voltage. Did you measure 115 volts AC?Go to Step 17Go to Step 14
9With the ignition ON and the power outlet switch on: Connect a test lamp between the INV relay coil feed circuit at the INV relay and ground. Did the test lamp illuminate?Go to Step 10Go to Step 18
10With the ignition ON and the power outlet switch on: Connect a test lamp between the INV relay switch side feed circuit and ground. Did the test lamp illuminate?Go to Step 11Go to Step 19
11With the ignition ON and the power outlet switch on: Connect a test lamp between the INV relay switch side load circuit and ground. Did the test lamp illuminate?Go to Step 20Go to Step 12
12Test the ground circuit of the 115 volt power outlet switch for continuity. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition?Go to Step 24Go to Step 15
13Inspect for poor connections at the harness connector of the 115 volt power outlet switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition?Go to Step 24Go to Step 21
14Inspect for poor connections at the harness connector of the accessory AC/DC power control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition?Go to Step 24Go to Step 23
15Inspect for poor connections at the harness connector of the INV relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition?Go to Step 24Go to Step 22
16Repair the open in the 115 volt power outlet switch feed circuit between the 115 volt power outlet switch and the GAUGE fuse. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?Go to Step 24
17Repair the open between the accessory AC/DC power control module and the 115 volt power outlet. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?Go to Step 24
18Repair the open in the INV relay coil feed circuit between the INV relay and the 115 volt power outlet switch. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?Go to Step 24
19Repair the open in the INV relay switch side feed circuit between the INV relay and the INV fuse. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?Go to Step 24
20Repair the open in the INV relay switch side load circuit between the INV relay and the accessory AC/DC power control module. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?Go to Step 24
21Replace the 115 volt power outlet switch. Refer to Power Outlet Receptacle Switch Replacement . Did you complete the replacement?Go to Step 24
22Replace the INV relay. Did you complete the replacement?Go to Step 24
23Replace the accessory AC/DC power control module. Refer to AC/DC Power Outlet Control Module Replacement . Did you complete the replacement?Go to Step 24
24Operate the system in order to verify the repair. Did you correct the condition?System OKGo to Step 1