Identification
Anomaly(ies) A: short circuit to earth at terminal 23
Anomaly(ies) B: short circuit to +ve at terminal 23
TEP 92
- Measure parameters: no OK
- Actuator test: no OK
| detection condition(s) | checks conditions for checking |
|---|---|
| - ignition on - engine running | engine running, check, by accelerating: - terminal 10 of the ECU 15V GR 0V 12V connector |