Home/Peugeot/406/Peugeot 406 I (1995-2003)/Repair manual/Power unit/Check: oxygen sensor function — variant 5
Contents Wiring diagrams Section: Power unit All sections

Check: oxygen sensor function — variant 5 Peugeot 406 I

ECU information available

Actuator test: no OK

Measure parameters: yes

Characterised by

  • Short circuit to positive
  • Coherence
  • Not specified (short circuit to positive, coherence)

Checks to be carried out if fault is present

Short circuit to positive

conditions under which the fault appearschecks to be made conditions for checking
engine runningverify: - ignition on, ECU connected: - no voltage at terminal(s) A3, B3 of the control unit 32 V.GR warning: if 12 V is present for 2/3 seconds after switching on the ignition, short circuit with a function supplied by +ve after relay

Coherence

conditions under which the fault appearschecks to be made conditions for checking
engine runningverify: - engine hot, engine running: - does the voltage U vary between terminals A3 and B3 of connector 32 V.GR of the ECU ? (0,1 ≤ U ≤ 1 V)

Not specified

conditions under which the fault appearschecks to be made conditions for checking
engine runningverify: - engine hot, engine running: - does the voltage U vary between terminals A3 and B3 of connector 32 V.GR of the ECU ? (0,1 ≤ U ≤ 1 V)

Check(s) to be carried out if no fault found

Engine hot, engine running, check:

- does the voltage U vary between terminals A3 and B3 of connector 32 V.GR of the ECU (0,1 ≤ U ≤ 1 V) ?

If incorrect: check continuity of wires A and B