Home/Peugeot/406/Peugeot 406 I (1995-2003)/Repair manual/Power unit/Check: 2 injectors control function
Contents Wiring diagrams Section: Power unit All sections

Check: 2 injectors control function Peugeot 406 I

ECU information available

Actuators test: yes

Parameter measurements: yes

Characterised by

  • Short circuit to positive
  • Short circuit to earth
  • Open circuit

Checks to be carried out if fault is present

Short circuit to positive

conditions under which the fault appearschecks to be made conditions for checking
engine runningignition on; engine management control unit, disconnected, injectors 2 connected: - no voltage at terminal(s) 53 of the control unit ignition off; engine management control unit, disconnected, injector(s) 2 disconnected: - check the insulation of wire A2 in relation to wire B - check resistance R of the injector between 15 and 17 Ω

Short circuit to earth

conditions under which the fault appearschecks to be made conditions for checking
engine runningignition off; engine management control unit, disconnected, injectors 2 connected: - no earth at terminal(s) 53 on the 88 V.NR connector

Open circuit

conditions under which the fault appearschecks to be made conditions for checking
engine runningignition on; engine management control unit, connected, injectors 2 connected: - check: presence of 12 V at terminal(s) 53 on connector 88 V.NR - check: resistance R of the injector between 15 and 17 Ω