Technical Data
| Refrigerant: | R 134a | Part�/ Catalogue No.: 90 443 833 / 19 40 447 |
| Fill quantity: | 910 g | |
| Compressor lubricant: | |
| Designation | Synthetic PAG oil |
| Overall capacity | 265 ml |
| Part/Catalogue No. | 90 443 840/19 49 871 |
| O�ring lubricant: | |
| Designation | Mineral oil |
| Part/Catalogue No. | 90 001 810/19 49 870 |
| Clearance | 0.38 - 0.69 mm |
| Pressure in the low pressure range: | 155 - 185 kPa |
| Pressure in the high pressure range: | 1400 - 2000 kPa |
Technical Data
X 22 Xe, X 30 Xe
| Switching Pressures | ON | OFF |
| Auxiliary fan switch S65: | | |
| Level 1 | 1500 kPa | 1100 kPa |
| Level 2 | 1900 kPa | 1500 kPa |
| Triple switch S20: | | |
| Low pressure | 250 kPa | 180 kPa |
| High pressure | 2000 kPa | 3000 kPa |
| Switching temperatures of the coolant temperature switches: | ON | OFF |
| S29 | 100 �C | 95 �C |
| S128 | Contact 1 | 115 �C | 120 �C |
| Contact 2 | 105 �C | 100 �C |
The maximum air flow rate is 150 l/s.
Technical Data
X 22 Dth
| Coolant switching temperatures | ON | OFF |
| Auxiliary fan | | |
| Level 1 | 102 �C | 98 �C |
| Level 2 | 107 �C | 103 �C |
| Compressor | 115 �C | 120 �C |
| Switching Pressures | ON | OFF |
| Compressor | | |
| High pressure | 1650 kPa | 2643 kPa |
| Low pressure | 413 kPa | 324 kPa |