Checking Program - Trouble Code 171 Opel Corsa B

Checking Program

Trouble CodeTrouble Code Storage when...
171Trouble code is stored if a short circuit to battery +, Ter. 30 or a lead interruption is recognized in the ambient temperature sensor circuit.
Notes on Trouble-shooting:Nominal Value:Cause of Fault:
(If nominal value is not attained)

· Disconnect connection plug from ambient temperature sensor P 13

· Using multimeter, measure resistance: between the two terminals of ambient temperature sensor P 13-30 °C/-22 °F

83.2 to 94.6 k

-20 °C/-4 °F

47.1 to 50.1 k

-10 °C/+ 14 °F

26.8 to 28.6 k· Check wiring harness plug for corrosion
· Ambient temperature sensor P 13 defective
0 °C/32 °F

15.8 to 16.9 k

10 °C/50 °F

9.6 to 10.3 k

20 °C/68 °F

6 to 6.5 k

30 °C/86 °F

3.9 to 4.2 k

40 °C/l04 °F

2.6 to 2.8 k

50 °C/l22 °F

1.7 to 1.9 k

· Measure voltage:

from: connection plug P 13

(cable colour: BLWS: blue/white)

to: connection plug P 13

(cable colour: BL: blue)4.5 V to 5.5 VVoltage greater than 5.5 V

· Short circuit in wiring harness

from: plug X 23 Ter. 4

to: battery +

· Short circuit in wiring harness

from: plug X 23 Ter. 2

to: battery +

· TID defective.

Voltage less than 4.5 V

· Short circuit in wiring harness

from: plug X 23 Ter. 4

to: ground

· Lead interruption

from: plug X 23 Ter. 4

to: connection plug P 13

(cable colour: BLWS: blue/white)

· Lead interruption.

from: plug X 23 Ter. 2

to: connection plug P 13

(cable colour: BL: blue)

· Remove TID

· Disconnect TID plug X 23

· Voltage:

from: wiring harness plug X 23 Ter. 4 and Ter. 2
to: ground0 V· Short circuit in wiring harness

from: wiring harness plug X 23 Ter. 4 and Ter. 2

to: battery +

· Using multimeter, measure resistance:

from: plug X 23 Ter. 4
to: plug X 23 Ter. 2¥· Short circuit in wiring harness

from: plug X 23 Ter. 4

to: plug X 23 Ter. 2

If nominal values are attained· TID defective

· If the ambient temperature display adapts only very slowly to the current ambient temperature, the following checks must be carried out.