Contents Wiring diagrams Section: Automatic HVAC System All sections

HVAC System - Automatic - Aurora: Specifications Oldsmobile Aurora II

SPECIFICATIONS

ApplicationSpecification
Compressor Type(1)
Compressor Belt Tension(2)
System Oil Capacity (3)9.7 oz
Refrigerant (R-134a) Capacity35 ozs.
System Operating Pressures (4)
High Side127-197 psi (8.9-13.8 kg/cm 2 )
Low Side25-34 psi (1.8-2.4 kg/cm 2 )
(1) Refer to underhood A/C specification label in engine compartment. (2) Engine is equipped with automatic serpentine belt tensioner. No adjustment is required. (3) Use PAG Oil (Part No. 12345923). (4) Approximate operating pressures with ambient temperature at 70°F (21°C) and engine at idle.
(1)Refer to underhood A/C specification label in engine compartment.
(2)Engine is equipped with automatic serpentine belt tensioner. No adjustment is required.
(3)Use PAG Oil (Part No. 12345923).
(4)Approximate operating pressures with ambient temperature at 70°F (21°C) and engine at idle.

SPECIFICATIONS

TORQUE SPECIFICATIONS

ApplicationFt. Lbs. (N.m)
A/C Refrigerant Line
Accumulator15 (20)
Compressor15 (20)
Condenser15 (20)
Orifice Solenoid20 (27)
Compressor Mounting
Front Nut37 (50)
Rear Bolt37 (50)
Rear Nut18 (25)
Right Front Frame Cradle (V-6)141 (191)
Instrument Panel Carrier Bolts18 (25)

TORQUE SPECIFICATIONS

Automatic A/C-Heater System Wiring Diagram (2001 Aurora - 1 Of 2). Scheme 1

Automatic A/C-Heater System Wiring Diagram (2001 Aurora - 2 Of 2). Scheme 2