INSPECTION AFTER INSTALLATION
- Check the engine oil level. Refer to " «INSPECTION»(ref-320190-S21592702432009071300000) ".
- Start the engine and check for engine oil leakage.
- Stop the engine and wait for 10 minutes.
- Check the engine oil level and add engine oil as required.
Scheme 7
Scheme 7: Changing Spark Plugs
Scheme 8
- Remove engine room cover using power tool. Refer to " «REMOVAL AND INSTALLATION»(ref-320185-S33486365092009071300000) ".
- Remove ignition coil. Refer to " «REMOVAL AND INSTALLATION»(ref-320185-S18432381202009071300000) ".
- Remove spark plug using suitable tool.
Scheme 9
Scheme 9: INSPECTION AFTER REMOVAL
Scheme 10
- Do not use a wire brush for cleaning.
- If plug tip is covered with carbon, spark plug cleaner may be used. Cleaner air pressure: Less than 588 kPa (5.9 bar, 6 kg/cm 2 , 85 psi) Cleaning time: Less than 20 seconds
- Checking and adjusting plug gap is not required between change intervals.