MAINTENANCE OF LUBRICANT QUANTITY IN COMPRESSOR

The lubricant in the compressor circulates through the system with the refrigerant. Add lubricant to compressor when replacing any component or after a large refrigerant leakage has occurred. It is important to maintain the specified amount.

If lubricant quantity is not maintained properly, the following malfunctions may result

  1. Lack of lubricant: May lead to a seized compressor
  2. Excessive lubricant: Inadequate cooling (thermal exchange interference)