SAFETY PRECAUTIONS

WARNINGWear safety goggles and gloves when servicing the refrigeration system to prevent severe damage to eyes and hands.

Because R-134a refrigerant is a hydro fluorocarbon (HFC) which contains hydrogen atoms in place of chlorine atoms, it will not cause damage to the ozone layer.

Ozone filters out harmful radiation from the sun. To assist in protecting the ozone layer, Mitsubishi Motors Corporation recommends an R-134a refrigerant recycling device.

Refrigerant R-134a is transparent and colorless in both the liquid and vapor state. Since it has a boiling point of -29.8°C (-21.64°F) at atmospheric pressure, it will be a vapor at all normal temperatures and pressures. The vapor is heavier than air, non-flammable, and non-explosive. The following precautions must be observed when handling R-134a.

WARNINGDo not heat R-134a above 40°C (104.0°F) or it may catch fire and explode.

R-134a evaporates so rapidly at normal atmospheric pressures and temperatures that it tends to freeze anything it contacts. For this reason, extreme care must be taken to prevent any liquid refrigerant from contacting the skin and especially the eyes. Always wear safety goggles when servicing the refrigeration part of the A/C system. Keep a bottle of sterile mineral oil handy when working on the refrigeration system.

  1. Should any liquid refrigerant get into your eyes, use a few drops of mineral oil to wash them out. R-134a is rapidly absorbed by the oil.
  2. Next, splash your eyes with plenty of cold water.
  3. Call your doctor immediately even if irritation has ceased.
CAUTIONKeep R-134a containers upright when charging the system.

In most instances, moderate heat is required to bring the pressure of the refrigerant in its container above the pressure of the system when charging or adding refrigerant.

A bucket or large pan of hot water not over 40°C (104.0°F) is all the heat required for this purpose. Do not heat the refrigerant container with a blow torch or any other means that would raise temperature and pressure above this temperature. Do not weld or steam-clean on or near the system components or refrigerant lines.

WARNINGA leak detector for R-134a should be used to check for refrigerant gas leaks.
CAUTIONDo not allow liquid refrigerant to touch bright metal or it will be stained.

When metering R-134a into the refrigeration system, keep the supply tank or cans in an upright position. If the refrigerant container is on its side or upside down, liquid refrigerant will enter the system and damage the compressor.

Refrigerant will tarnish bright metal and chrome surfaces, and in combination with moisture can severely corrode all metal surfaces.

CONDENSER FAN AND RADIATOR FAN CONTROL

The ECM judges the required revolution speed of radiator fan motor and condenser fan motor using the input signals transmitted from A/C switch, output shaft speed sensor and engine coolant temperature sensor.

COMPRESSOR CONTROL

When operating the A/C switch

  1. The air thermo sensor, which senses the temperature of the air flowing out of the evaporator, deactivates the compressor at 1°C (33.8°F) or below.
  2. A/C-ECU detect refrigerant pressure by A/C pressure sensor and turns OFF when the refrigerant pressure becomes excessively high or low, thus protecting the compressor circuit (See «A/C COMPRESSOR CLUTCH RELAY ON CONDITIONS»(ref-593021-S13699684212014011300000) ).
  3. When the air thermo sensor is activated, and the ignition switch, blower switch, and A/C switch are ON, the A/C compressor clutch relay is energized.

When operating the mode selection dial

  1. The A/C will work when the mode selection dial is set to the "Defroster" or "Defroster/foot" position, or the temperature control dial is set to the "MAX A/C" position. In other dial positions, when the A/C switch is turned on, the A/C will work.

A/C Compressor Clutch Relay ON Conditions

Ignition switch (IG2)ONNOTE: A/C compressor clutch relay is de-energized when any one switch, sensor or control unit shown on the left turns off. NOTE: The components marked by * communicate with the ECU. If the air thermo sensor detects a temperature of 1°C (33.8°F), the A/C-ECU will turn off the A/C compressor clutch relay.
Blower switchON
A/C switch, mode selection dial defroster, defroster/foot position or temperature control MAX A/CON
Air thermo sensor*
Pressure detected by A/C pressure sensor2.94 MPa (427psi) or less (If the refrigerant pressure exceeds 2.94 MPa (427psi), A/C compressor clutch relay is not ON condition until the refrigerant pressure has been measured up to 2.35 MPa (341psi) a or less.)ON
0.19 MPa (27psi) or more (If the refrigerant pressure falls short of 0.19 MPa (27psi), A/C compressor clutch relay is not ON condition until the refrigerant pressure has been measured up to 0.22 MPa (32psi) or more.)
A/C compressor clutch relay driving transistor (within powertrain control module)ON
NOTE
A/C compressor clutch relay is de-energized when any one switch, sensor or control unit shown on the left turns off.
NOTE
The components marked by * communicate with the ECU. If the air thermo sensor detects a temperature of 1°C (33.8°F), the A/C-ECU will turn off the A/C compressor clutch relay.

A/C COMPRESSOR CLUTCH RELAY ON CONDITIONS

HOW TO READ DATA LIST

Required Special Tools

  1. MB991958: Scan Tool (M.U.T.-III Sub Assembly) MB991824: Vehicle Communication Interface (V.C.I.) MB991827: M.U.T.-III USB Cable MB991910: M.U.T.-III Main Harness A (Vehicles with CAN communication system)
CAUTIONTo prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
  1. Connect the scan tool MB991958 to the data link connector.
  2. Turn the ignition switch to the "ON" position.
  3. Select "Interactive Diagnosis" from the start-up screen.
  4. Select "System Select." Select "AUTO A/C" from "System List," and press the "OK" button.
  5. Select "Data List."
  6. Choose an appropriate item and select the "OK" button.

CHECK OF FREEZE FRAME DATA

The freeze frame data can be checked by using the scan tool. HOW TO COPE WITH INTERMITTENT MALFUNCTION ).

When detecting fault and storing the DTC, the ECU connected to CAN bus line obtains the data before the determination of the DTC and the data when the DTC is determined, and then stores the ECU status of that time. By analyzing the data from scan tool, the troubleshooting can be performed more efficiently. The displayed items are as shown in the table below.

Display item list

Item No.Item nameData itemUnit
01OdometerTotal driving distance after the diagnostic trouble code is generatedMile (1)
02Ignition cycleNumber of times the ignition switch is turned "ON" or "LOCK (OFF)" after the past failure transitionNumber of counts is displayed.
04Current trouble accumulative timeCumulative time for current malfunction of diagnostic trouble codeMin
(1) If a failure occurs to both the ABS-ECU and ETACS-ECU, 0000 km or FFFF mile is displayed to the scan tool MB991958.
(1)If a failure occurs to both the ABS-ECU and ETACS-ECU, 0000 km or FFFF mile is displayed to the scan tool MB991958.

FREEZE FRAME DATA

DATA LIST REFERENCE TABLE

Scan tool displayItem No.The display contents under normal conditions
Engine speed17Displays correct engine speed.
Ambient temperature sensor19Ambient temperature is the same as scan tool displayed temperature
Air thermo sensor20Evaporator outlet temperature is the same as scan tool displayed temperature.
Interior temperature sensor21Interior temperature is the same as scan tool displayed temperature
Temperature setting23Displays air conditioning set temperature.
ETC sensor24Engine coolant temperature is the same as scan tool displayed temperature.
Vehicle speed26Displays vehicle speed.
A/C Compressor drive request27Compressor ON
Compressor OFF
Air conditioning switch28Air conditioning switch ON
Air conditioning switch OFF
Refrigerant leak29Normal
Idle up request34Displays idle-up request signal.
Rear heater SW light (1)35
PTC heater 1 (1)36
PTC heater 2 (1)37
PTC heater 3 (1)38
In/out select damp poten (target)45Displays outside/inside air selection damper target position.
In/out select damp potentiometer46Displays outside/inside air selection damper position.
Air outlet c/o potentiometer55Displays air outlet changeover damper position.
Air outlet c/o potentio. (Target)56Displays air outlet changeover damper target position.
Low pressure judgment57Normal
Rear defogger switch60ON Rear window defogger switch ON
OFF Rear window defogger switch OFF
Pressure sensor61Displays refrigerant pressure.
Air mix potentiometer63Displays the air mix damper position.
Photo sensor (1)67
Front blower fan68Displays blower motor condition.
Front blower fan (Target)69Displays blower motor target value.
Refrigerant pressure73Displays refrigerant pressure status.
Condenser fan74Displays condenser fan running condition.
Temp. set dial position76Displays the set temperature output value on the control panel.
A/C Panel type77Dial/Auto/RHD
Fan set dial position78Displays the air volume output value on the control panel.
Air outlet c/o set dial position79Displays output value to the air outlet changeover dial on the control panel.
Fan set dial operation flag80ON when the air volume adjusting dial is operated
A/C SW operation flag81ON when the air conditioning switch is operated
Temp. set dial operation flag82ON when the air conditioning switch is operated
Defogger flag (1)83
In/out air c/o SW operation flag (1)84
Rear defogger SW operation flag (1)87
Rear defogger SW light88Displays rear window switch indicator status.
A/C SW light89Displays air conditioning switch indicator status.
In/out air c/o SW light90Displays the status of the inside air/outside air changeover switch indicator.
A/C Compressor drive flag91ON when the compressor is activated.
Wiper operation flag92ON when the wiper is operated.
Ignition position information93Ignition switch position status
Power source voltage94Displays power supply voltage.
IOD fuse equipment flag95IOD fuse status
A/T lock up open request96
System operation time100
Compressor use times101
Rear defogger use times102
In/out air c/o poten drive time103
Air outlet c/o poten drive time104
Air mix potentiometer drive time105
Hot state time (Interior TEMP.)106
Cold state time (Interior TEMP.)107
Hot state time (Ambient TEMP.)108
Cold state time (Ambient TEMP.)109
Maximum ambient temperature110
Minimum ambient temperature111
Maximum Engine coolant TEMP.112
Engine high speed time113
Maximum Engine speed114
High pressure drive time115
High pressure cut times116
Maximum pressure (kPa)117
A/C use rate118
Compressor operation rate119
Eco operation rate120
Recirc use rate121
A/C operation times122
In/out air c/o operation times123
Mode dial operation times124
Blower fan dial operation times125
TEMP. set dial operation times126
FACE mode use rate127
B/L mode use rate128
FOOT mode use rate129
D/F mode use rate130
DEF mode use rate131
Fan OFF use rate132
Fan 1-2step use rate133
Fan 3-4step use rate134
Fan 5-6step use rate135
Fan 7-8step use rate136
Temp 1-7 step use rate137
Temp 8-10step use rate138
Temp 11-13 step use rate139
Temp 17-19step use rate140
Temp 20-22step use rate141
Temp 23-29step use rate142
PTC heater1 use times (1)143
PTC heater2 use times (1)144
PTC heater3 use times (1)145
Fan LO driving time146
Fan M1 driving time147
Fan M2 driving time148
Fan HI driving time149
Rear PTC heater counter (1)150
(1) shows that it is displayed but not used.
(1)Shows that it is displayed but not used.

DATA LIST REFERENCE

INTERIOR TEMPERATURE SENSOR CHECK

Check to see that the resistance see scheme 10is almost satisfied when measuring the resistance between the terminals under two or more different temperature conditions.

Scheme 8

Scheme 8: INTERIOR TEMPERATURE SENSOR CHECK