TECHNICAL DESCRIPTION (COMMENT)
The ETACS-ECU sets DTC B16A2 under the following conditions.
- If there is a malfunction to the left turn-signal light bulb, the blown left bulb counter counts once when the illumination of hazard or turn-signal light (left side) is attempted.
- After the bulb counter reaches "3," DTC B16A2 is set.