ENGINE COOLANT CONCENTRATION TEST
Scheme 107
Scheme 107: FAN CONTROL MODULE CHECK
- Remove the fan control module connector.
- Turn the ignition switch to the "ON" position, and measure the voltage between the harness-side connector terminals. Standard value: Battery positive voltage
- Connect the fan control module connector, and disconnect the condenser fan motor connector.
- Ensure that the A/C switch is off, and start the engine and run it at idle.
- Measure the voltage between the fan control module-side connector terminals. Standard value: 1V or less
- Turn the A/C switch to the "ON" position. WARNING: Stay clear of the fan when the fan starts running.
- Measure the voltage between the fan control module-side connector terminals while the fan is running. The voltage should repeat the values 1) and 2) below. Standard value: 1) 8.2 +/- 2.6 V 2) Battery positive voltage +/- 2.6 V
- If the voltage does not repeatedly change as indicated, replace the fan control module.
Scheme 108
Scheme 109
Scheme 109: FAN CONTROL RELAY CONTINUITY CHECK
Scheme 110