ACTUATOR TEST REFERENCE

MUT-III SCAN TOOL DISPLAYITEM NO.INSPECTION ITEMDRIVE CONTENT
Rear defogger switch: OFF35Rear window defogger switchRear window defogger: OFF
Rear defogger switch: ON36Rear window defogger: ON
Air mix damper motor: 0%42Air mixing damper control motorOpening degree: approx. 0% (Max cool)
Air mix damper motor: 100%43Opening degree: approx. 100% (Max hot)
Air mix damper motor: 50%44Opening degree: approx. 50%
Air outlet c/o dumper: Bi_Level67Mode selection damper control motorFOOT/FACE
Air outlet c/o dumper: DEF68DEF
Air outlet c/o dumper: DEF/FOOT69DEF/FOOT
Air outlet c/o dumper: FACE70FACE
Air outlet c/o dumper: FOOT71FOOT
In/out changeover damper: Fresh72Outside/inside air selection damper control motorOutside
In/out changeover damper: Recirc73Inside
Idle up request: high load74Idle up operationIdle up: high load
Idle up request: low load75Idle up: low load
Idle up request: OFF76Idle up: OFF
Condenser fan: OFF77Condenser fanOFF
Condenser fan: 100%78High speed
Condenser fan: 50%79Middle speed
Front blower fan: OFF83Blower motorOFF
Front blower fan: Middle84Middle speed
Front blower fan: High85High speed

ACTUATOR TEST REFERENCE

Scheme 380

Scheme 380: CHECK AT A/C-ECU TERMINAL
TERMINAL NO.CHECK ITEMCHECKING REQUIREMENTSNORMAL CONDITION
1Air mixing damper control motorWhen the air mix damper is moved to the MAX. COOL position.10 V
When the air mix damper is moved to the MAX. HOT position.0.5 V
2Air mixing damper control motorWhen the air mix damper is moved to the MAX. COOL position.0.5 V
When the air mix damper is moved to the MAX. HOT position.10 V
3Back-up power supplyAlwaysBattery positive voltage
4Mode selection damper control motor (DEF)When the damper is moved to the FACE position.0.5 V
When the damper is moved to the DEF position.10 V
5Outside/inside air selection damper control motor (outside)When the damper is moved to the inside air recirculation position.0.5 V
When the damper is moved to the outside air induction position.0 V (when the motor is stopped)
6Outside/inside air selection damper control motor (inside)When the damper is moved to the inside air recirculation position.0 V (when the motor is stopped)
When the damper is moved to the outside air induction position.0.5 V
8Rear defogger relayIgnition switch: ONBattery positive voltage
9Front blower relayIgnition switch: ONBattery positive voltage
10A/C compressor relayA/C compressor relay: ONBattery positive voltage
11Mode selection damper control motor (FACE)When the damper is moved to the FACE position.10 V
When the damper is moved to the DEF position.0.5 V
12A/C pressure sensorIgnition switch: ON5 V
16Potentiometer power supplyIgnition switch: ON5 V
17Power transistor (BASE)When the blower speed selection dial shows Maximum air volume.1 V
18Power transistor (COLLECTOR)When the blower speed selection dial shows Maximum air volume.12.1 V
19Photo sensorIgnition switch: ON5 V
20Sensors and potentiometers groundAlways0 V
21Mode selection damper control motor potentiometer inputWhen the damper is moved to the FACE position.4 V
22Interior temperature sensorIgnition switch: ON5 V
23Ambient temperature sensor inputWhen sensor temperature is 25°C (77°F) [4 kohms]1.9 V
24Air thermo sensor inputWhen sensor temperature is 25°C (77°F) [1.5 kohms]2.2 V
25Photo sensor groundIgnition switch: ON0 V
26A/C pressure sensorAt 2.6 MPa (377 psi)3.9 V
27GroundAlways0 V
28Power supply to the ignition switch (IG2)Ignition switch: ONBattery positive voltage
29Air mixing damper control motor potentiometer inputWhen the damper door is moved to the MAX. HOT position.1.4 V
30Illumination groundAlways0 V
31ILL power supplyLighting switch: ONBattery positive voltage
34A/C pressure sensor groundAlways0 V
36Power supply to the ignition switch (ACC)Ignition switch: ONBattery positive voltage

TERMINALS VOLTAGE CONDITIONS