SERVICE SPECIFICATIONS

ITEMSSTANDARD VALUELIMIT
Generator
Regulated voltage (Ambient temperature at voltage regulator)20°C (- 4°F)14.2 - 15.4
20°C (68°F)13.9 - 14.9
60°C (140°F)13.4 - 14.6
80°C (176°F)13.1 - 14.5
Generator output line voltage drop (at 30 A) VMaximum 0.3
Output current70 % of normal output current
Field coil resistance ohmApproximately 2 - 5
Brush protrusion length mm (in)Minimum 2 (0.08)
Starter motor
Free running characteristicsTerminal voltage V11
Current A90
Speed r/min2,000 or more
Pinion gap mm (in)0.5 - 2.0 (0.02 - 0.07)
Commutator run-out mm (in)0.05 (0.002)Minimum 0.1 (0.004)
Commutator diameter mm (in)29.4 (1.16)Minimum 28.8 (1.13)
Undercut depth mm (in)0.5 (0.02)Minimum 0.2 (0.008)
Ignition parts
Spark plug gap mm (in)2.4L Engine0.7 - 0.8 (0.028 - 0.031)1.2 (0.047)
3.8L Engine0.7 - 0.8 (0.028 - 0.031)0.95 (0.037)

SERVICE SPECIFICATIONS (2.4L & 3.8L)