Contents Wiring diagrams Section: Manual HVAC System All sections

HVAC Control System: Specifications Mercury Sable V

GENERAL SPECIFICATIONS

ItemSpecification
Magnetic Clutch
Air gap between pulley and clutch plate0.35-0.65 mm (0.014-0.026 in)

GENERAL SPECIFICATIONS

TORQUE SPECIFICATIONS TABLE

DescriptionNm
A/C compressor bolts25
A/C compressor fitting nuts (suction and discharge)15
A/C compressor mounting stud9
A/C compressor nut25
A/C compressor pressure relief valve10
A/C clutch disc and hub bolt14
Auxiliary evaporator inlet line fitting nut15
Auxiliary evaporator outlet line fitting nut15
Condenser bolts6
Condenser fitting nuts (inlet and outlet)15
Cross-vehicle beam nuts30
Evaporator inlet line fitting nut15
Evaporator outlet line fitting nut15
Heater core and evaporator core housing bolts9
High-pressure Schrader-type valve2.5
High-pressure service gauge port valve cap0.8
Low-pressure Schrader-type valve1.8
Low-pressure service gauge port valve cap0.8
Receiver/drier outlet fitting nut15
Roll restrictor bracket bolt48
Thermostatic expansion valve (TXV) bolts8
TXV fitting bolt8
TXV manifold and tube bracket bolt9

TORQUE SPECIFICATIONS TABLE