Typical Diagnostic Reference Values (2.5L)
| Actuators/Outputs | PCM Pin/PID only | Measured/PID Values | Units Measured/PID | |||
|---|---|---|---|---|---|---|
| KOEO | Hot Idle | 30 mph | 55 mph | |||
| FP | C19 | 75 | 40.04 | 40.09 | 40.29 | % |
| WAC/ACCR | C12 | VBAT/OFF | 1.5/ON | VBAT/OFF | VBAT/OFF | DCV/OFF-ON |
| EVAPCV | C20 | 0/OFF | 0/OFF | 0/OFF (R) | 0/OFF (R) | % ON-OFF |
| GENCMD | C53 | 3.57 | 0(Q) | 0(Q) | 0(Q) | % |
| HFC | PID | OFF | ON(B) | OFF | OFF | OFF-ON |
| LFC | PID | OFF | ON(B) | OFF | OFF | OFF-ON |
| GENCMD | C53 | 3.79 | 0(Q) | 0(Q) | 0(Q) | % |
| HTR11 | E69 | OFF | ON | ON | ON | OFF-ON |
| SSC (SS3) (A/T) | T23 | VBAT/OFF | VBAT/OFF | 8.8/OFF | 8.8/OFF | DCV/ON-OFF |
| SSA(SS1) (A/T) | T42 | VBAT/OFF | VBAT/OFF | VBAT/OFF | 0.1/ON | DCV/ON-OFF |
| SSB(SS2) (A/T) | T43 | 0.1/ON (O) | 0.1/ON | VBAT/OFF | VBAT/OFF | DCV/ON-OFF |
| TCC (A/T) | PID | 0 | 0 | 19.14 | 27.55 | PSI |
| HTR12 | T49 | OFF (O) | ON | ON | ON | OFF-ON |
| CAT_EVAL | PID | YES | YES | YES | YES | YES/NO |
| EVAPCV | PID | 0/OFF | 0/OFF | 0/OFF (R) | 0/OFF (R) | %/ON-OFF |
| EVAPSOAK | PID | NO | NO | NO | NO | YES/NO |
| FAN | PID | OFF | OFF | OFF | OFF | ON-OFF |
| FCIL | PID | OFF | OFF | OFF | OFF | ON-OFF |
| FUELSYS | PID | OPEN LOOP | CLOSED LOOP | CLOSED LOOP | CLOSED LOOP | OPEN LOOP/CLOSED LOOP |
| LONGFT1 | PID | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | % |
| LONGFT2 | PID | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | % |
| PATSENABL | PID | ENABLED | ENABLED | ENABLED | ENABLED | ENABLED/DISABLED |
| RPMDSD | PID | 650 | 650 | 650 | 650 | RPM |
| SHRTFT1 | PID | (U | (-)10-(+)10 | (-)10-(+)10 | (-)10-(+)10 | % |
| SPARKADV (A/T) | PID | 10 | 14-20 | 36-44 | 30-40 | DEG |
| SPARKADV (A/T) | PID | 10 | 14-20 | 45.25 | 53 | DEG |
| STRT_RLY | PID | ENABLED | DISABLED | DISABLED | DISABLED | ENABLED/DISABLED |
| TCIL (A/T) | PID | OFF | OFF | OFF | OFF | ON-OFF |
| TPCT | PID | 0.85 | 0.84 | 0.85 | 0.85 | DCV |
| TQ_CNTRL | PID | NONE | NONE | NONE | NONE | |
| Volt Meter | PCM Pin/PID Only | KOEO | Hot Idle | 48 KM/H (30 MPH) | 89 KM/H (55 MPH) | Units Measured/PID |
| VPWR | C67/68 | 12.39 | 13-14 | 13-14 | 13-14 | DCV |
TYPICAL DIAGNOSTIC REFERENCE VALUES CHART
Typical Diagnostic Reference Values (3.0L 4V])
| Actuators/Outputs | PCM Pin/PID Only | Measured/PID Values | Units Measured/PID | |||
|---|---|---|---|---|---|---|
| KOEO | Hot Idle | 30 mph | 55 mph | |||
| FP | B19 | 75 | 40.04 | 40.09 | 40.29 | % |
| HFC | PID | OFF | ON (B) | OFF | OFF | ON-OFF |
| LFC | PID | OFF | ON (B) | OFF | OFF | ON-OFF |
| HTR21 | E70 | OFF (O) | ON | ON | OFF (O) | ON-OFF |
| HTR11 | E69 | OFF | ON | ON | OFF | ON-OFF |
| TCC | PID | 0 | 0 | 22.04 | 40.89 | PSI |
| HTR12 | T49 | OFF | ON | ON | ON | ON-OFF |
| HTR22 | T48 | OFF | ON | ON | ON | ON-OFF |
| CAT_EVAL | PID | NO | NO | NO | NO | YES/NO |
| EVAPCV | C20/PID | 0/OFF | 0/0FF | 0/0FF | 0/0FF | %/ON-OFF |
| GENCMD | C53 | 3.57 | 0(Q) | 0(Q) | 0(Q) | % |
| EVAPCP | E32 | 0 | 56.08 | 20.39 | 0 | %/ON-OFF |
| EVAPSOAK | PID | YES | YES | YES | YES | YES-NO |
| FCIL | PID | OFF | OFF | OFF | OFF | ON-OFF |
| FTP_H2O | PID | 0.06 | 1.03 | 1.03 | 0.06 | In_H2O |
| FUELSYS | PID | OPEN LOOP | CLOSED LOOP | CLOSED LOOP | CLOSED LOOP | OPEN LOOP/CLOSED LOOP |
| LONGFT1 | PID | (L) | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | % |
| LONGFT2 | PID | (L) | (-)20-(+)20 | (-)20-(+)20 | (-)20-(+)20 | % |
| PATSENABL | PID | ENABLED | ENABLED | ENABLED | ENABLED | ENABLED/DISABLED |
| RPMDSD | PID | 680 | 680 | 650 | 650 | RPM |
| SHRTFT1 | PID | (L) | (-)10-(+)10 | (-)10-(+)10 | (-)10-(+)10 | % |
| SHRTFT2 | PID | (L) | (-)10-(+)10 | (-)10-(+)10 | (-)10-(+)10 | % |
| SPARKADV | PID | 26.75 | 5-20 | 36-44 | 43.5 | DEG |
| STRT_RLY | PID | DISABLED | DISABLED | DISABLED | DISABLED | ENABLED/DISABLED |
| TCIL | PID | OFF | OFF | OFF | OFF | ON/OFF |
| TQ_CONTRL | PID | NONE | NONE | NONE | NONE | |
| Other | PCM Pin/PID only | KOEO | Hot Idle | 48 KM/H (30 MPH) | 89 KM/H (55 MPH) | Units Measured/PID |
| VPWR | C67/68 | 12.06 | 13-14 | 13-14 | 13-14 | DCV |
TYPICAL DIAGNOSTIC REFERENCE VALUES CHART
Programmable Module Installation (PMI) Using the Integrated Diagnostic System (IDS) When the Original Module is Available
Note. Following module installation, some modules require a separate learning procedure be carried out. For adaptive learning and calibration instructions, refer to the specific module removal and installation procedures.
- Connect the IDS and identify the vehicle as normal.
- From the Toolbox icon, select Module Programming and press the check mark.
- Select Programmable Module Installation.
- Select the module that is being replaced.
- Follow the on-screen instructions, turn the ignition key to the OFF position, and press the check mark.
- Install the new module and press the check mark.
- Follow the on-screen instructions, turn the ignition key to the ON position, and press the check mark.
- The IDS downloads the data into the new module and displays Module Configuration Complete.
- Test module for correct operation.
Programmable Module Installation (PMI) Using the Integrated Diagnostic System (IDS) When the Original Module is NOT Available
Note. Following module installation, some modules require a separate learning procedure be carried out. For adaptive learning and calibration instructions, refer to the specific module removal and installation procedures.
- Install the new module.
- Connect the IDS and identify the vehicle as normal.
- From the Toolbox icon, select Module Programming and press the check mark.
- Select Programmable Module Installation.
- Select the module that is being replaced.
- Follow the on-screen instructions, turn the ignition key to the OFF position, and press the check mark.
- Follow the on-screen instructions, turn the ignition key to the ON position, and press the check mark.
- If the data is not available, the IDS displays a screen stating to contact the As-Built Data Center. Retrieve the data from the technician service publication website at this time and press the check mark.
- Enter the module data and press the check mark.
- The IDS downloads the data into the new module and displays Module Configuration Complete.
- Test module for correct operation.