SEAT WEIGHT SENSOR CALIBRATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM]
| CAUTION | If any of the following work is performed, perform the seat weight sensor calibration using the M-MDS. Replacement with a new seat weight sensor Replacement with a new seat weight sensor control module Replacement with new passenger-side seat parts Disassembly of the passenger-side seat If any of the following work is performed, perform the seat weight sensor inspection using the M-MDS. (See SEAT WEIGHT SENSOR INSPECTION [TWO-STEP DEPLOYMENT CONTROL SYSTEM] ). Removal of the passenger-side seat Loosening and retightening of passenger's seat fixing bolts Or, the vehicle is involved in a collision |
Note. When seat weight sensor calibration is performed causing the SAS control module to detect the DTC, perform the following procedure.
- Have two 20 kg {44 lb} weights ready to use.
- Connect the M-MDS to the DLC-2.
- After the vehicle is identified, select the following items from the initialization screen of the M-MDS. Select "Body". Select "SWS Calibration".
- Perform calibration following the procedures on the M-MDS screen.