Principles of Operation
Voltage is supplied to the roof opening panel motor at all times through circuit 30-AG12 (RD/GN) with the motor being grounded by circuit 31-AG12 (BK/GN). The driver door module (DDM) provides the delayed accessory power on circuit 10-AJ43B (GY/VT) and also the global open/close signal on circuit 8-AJ43B (WH/BU). Since the roof opening panel motor is always powered, the delayed accessory circuit is actually used by the smart motor to determine key position (key OFF, key ON).
With the delayed accessory circuit powered, the roof opening panel smart motor will operate as per the command supplied by the voltage input from the roof opening panel control switch on circuits 32-AG10 (WH/BU) (OPEN), 9-AG7 (BN/RD) common, 32-AG12 (WH/GN) (TILT UP), 33-AG10 (YE/BU) (CLOSE). The commands may include either a one-touch (express) open or close, proportional open or close, vent open or close.
The global open function will occur if the unlock button is pressed and held for two seconds. The driver door module (DDM) will receive the input from the transmitter and will transmit a signal over the global open/close circuit 8-AJ43 (WH/BU) to the roof opening panel smart motor. The microprocessor (which makes it a "smart" motor) in the smart motor will determine which global function to carry out and will then do so. If the key is turned in the driver door lock cylinder to the unlock position and held for two seconds (for global open) or to the lock position and held for two seconds (for global close), the DDM will process these inputs and send the appropriate global open/close signal to the roof opening panel smart motor.
Normal Operation
When the roof opening panel glass is completely closed, it should be flush with the roof panel.
When the roof opening panel glass is completely closed, it should be flush with the roof panel.
When the roof opening panel glass is completely closed, it should be flush with the roof panel. All components should be secured correctly.
The roof opening panel should operate smoothly while opening and closing.
PINPOINT TEST D: THE ROOF OPENING PANEL IS NOISY DURING OPERATION
- D1 CHECK THE ROOF OPENING PANEL FOR OBSTRUCTIONS OR DAMAGE Check the roof opening panel for any obstructions and damage. Are there any obstructions or damage? Yes : REMOVE all obstructions. REPAIR any damage or INSTALL a new roof opening panel. REFER to «ROOF OPENING PANEL»(ref-207570-S40093324652005113000000) . REINITIALIZE the roof opening panel. REFER to «ROOF OPENING PANEL MOTOR INITIALIZATION»(ref-207570-S39240458662005113000000) . TEST the system for normal operation. No : GO to D2.
- D2 CHECK THE ROOF OPENING PANEL OPERATION Check the roof opening panel during operation. Is the roof opening panel loose or incorrectly adjusted? Yes : ADJUST the roof opening panel. REFER to «ROOF OPENING PANEL ALIGNMENT»(ref-207570-S12476489112005113000000) . REINITIALIZE the roof opening panel. REFER to «ROOF OPENING PANEL MOTOR INITIALIZATION»(ref-207570-S39240458662005113000000) . TEST the system for normal operation. No : GO to D3.
- D3 CHECK THE ROOF OPENING PANEL TRACKS Open the roof opening panel. Check the roof opening panel tracks for obstructions and damage. Are the roof opening panel tracks OK? Yes : GO to D4. No : REMOVE all obstructions and REPAIR any damage. REINITIALIZE the roof opening panel. REFER to «ROOF OPENING PANEL MOTOR INITIALIZATION»(ref-207570-S39240458662005113000000) . TEST the system for normal operation.
- D4 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES Check the roof opening panel lifter assemblies for obstructions and damage. Are the roof opening panel lifter assemblies OK? Yes : GO to D5. No : REMOVE all obstructions and REPAIR any damage. REINITIALIZE the roof opening panel. REFER to «ROOF OPENING PANEL MOTOR INITIALIZATION»(ref-207570-S39240458662005113000000) . TEST the system for normal operation.
- D5 CHECK THE ROOF OPENING PANEL MOTOR Gain access to the roof opening panel motor. Open the roof opening panel. Does the roof opening panel motor make excessive noise? Yes : INSTALL a new roof opening panel motor. REFER to «ROOF OPENING PANEL»(ref-207570-S40093324652005113000000) . REINITIALIZE the roof opening panel. REFER to «ROOF OPENING PANEL MOTOR INITIALIZATION»(ref-207570-S39240458662005113000000) . TEST the system for normal operation. No : ADJUST the roof opening panel. REFER to «ROOF OPENING PANEL»(ref-207570-S40093324652005113000000) . REINITIALIZE the roof opening panel. REFER to «ROOF OPENING PANEL MOTOR INITIALIZATION»(ref-207570-S39240458662005113000000) . TEST the system for normal operation.
The roof opening panel motor is energized by voltage on circuit 30-AG12 (RD/GN). The roof opening panel motor is grounded through circuit 31-AG12 (BK/GN). When the roof opening panel control switch is pressed it connects circuit 32-AG12 (WH/GN) to circuit 9-AG7 (BR/RD) for tilt up. When the roof opening panel control switch is slid to the open position and released it will connect circuit 32-AG10 (WH/BU) to circuit 9-AG7 (BN/RD) for open. When the roof opening panel control switch is slid to the close position and released it will connect circuit 33-AG10 (YE/BU) to circuit 9-AG7 (BN/RD) for close.
The roof opening panel motor is energized by voltage on circuit 30-AG12 (RD/GN). The roof opening panel motor is grounded through circuit 31-AG12 (BK/GN). When the roof opening panel control switch is slid to the open position and released it will connect circuit 32-AG10 (WH/BU) to circuit 9-AG7 (BN/RD) for open. When the roof opening panel control switch is slid to the close position and released it will connect circuit 33-AG10 (YE/BU) to circuit 9-AG7 (BN/RD) for close.
The roof opening panel motor is energized by voltage on circuit 30-AG12 (RD/GN). The roof opening panel motor is grounded through circuit 31-AG12 (BK/GN). When the roof opening panel control switch is pressed, it connects circuit 32-AG12 (WH/GN) to circuit 9-AG7 (BR/RD) for tilt up. When the roof opening panel control switch is slid to the close position and released it will connect circuit 33-AG10 (YE/BU) to circuit 9-AG7 (BN/RD) for close.
The roof opening panel motor is energized by voltage on circuit 30-AG12 (RD/GN). The roof opening panel motor is grounded through circuit 31-AG12 (BK/GN). When the global open or close feature is activated the DDM sends a signal via circuit 8-AJ43 (WH/BU) to the roof opening panel motor. The global open/close will not function when the delayed accessory is active.
When the roof opening panel control switch is placed in the second detent of the open position the roof opening panel opens automatically to the full-open position. When the roof opening panel control switch is placed in the second detent of the close position, the roof opening panel closes automatically to the full-close position.