Contents Section: Cooling System (Mechanical) All sections

Cooling (Service Specifications): Other Lexus LS III рестайлинг

SERVICE DATA

Radiator capRelief Valve opening pressure STD93 - 123 kPa (0.95 - 1.25 kgf/cm 2 , 13.5 - 17.8 psi)
Minimum78kPa (0.8 kgf/cm 2 , 11.4 PSI)
Electric cooling fanRotating amperage at 20°C (68°F)9.2 - 11.0 A
Cooling fan computer wire harness amperage9 - 14 V
ThermostatValve opening temperature80 -84°C (176 - 183°F)
Valve lift at 95°C (203°F)10 mm (0.39 in.) or more