Home/Land Rover/Range Rover/Land Rover Range Rover II (1994-2002)/Repair manual/Sensor Range Charts/Engine Controls - Sensor Operating Range Charts - 4.0l & 4.…
Contents Section: Sensor Range Charts All sections

Engine Controls - Sensor Operating Range Charts - 4.0l & 4.6l Land Rover Range Rover II

SPECIFICATIONS

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.

Note. Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.

ComponentOhms
Crankshaft Position Sensor1235-1365
EVAP Purge Control Valve20-40
Fuel Injector15.7-16.7
HO2S Heater5.7
IAC Stepper Motor Coil51-55
Ignition Coil
Primary Coil0.8
Secondary Coil13,000
Throttle Position Sensor3200-4800

COMPONENT RESISTANCE VALUES

Temperature °F (°C)(1) OhmsOutput Voltage
22 (-30)28,0004.70
14 (-10)90004.20
68 (20)25002.70
104 (40)10502.00
140 (60)6001.20
176 (80)3300.75
266 (130)900.25
(1) Values are approximate.
(1)Values are approximate.

ENGINE COOLANT TEMPERATURE SENSOR RESISTANCE

Temperature °F (°C)(1) Ohms
22 (-30)23,000-32,000
14 (-10)8400-10,200
68 (20)2350-2650
104 (40)1000-1300
140 (60)520-670
176 (80)290-365
(1) Resistance values are approximate.
(1)Resistance values are approximate.

ENGINE FUEL TEMPERATURE SENSOR RESISTANCE

Temperature °F (°C)(1) Ohms
22 (-30)23,000-32,000
14 (-10)8400-10,200
68 (20)2350-2650
104 (40)1000-1300
140 (60)520-670
176 (80)290-365
(1) Resistance values are approximate.
(1)Resistance values are approximate.

INTAKE AIR TEMPERATURE SENSOR RESISTANCE

AirflowOutput Voltage
MinimumZero
0.3 lbs/min (0.1 kg/min)0.8
0.4 lbs/min (0.2 kg/min)1.0
0.5 lbs/min (0.2 kg/min)1.1
Engine @ Idle1.4
1.2 lbs/min (0.5 kg/min)1.6
2.1 lbs/min (1.0 kg/min)2.0
3.7 lbs/min (1.7 kg/min)2.4
6.0 lbs/min (2.7 kg/min)2.8
8.6 lbs/min (3.9 kg/min)3.1
11.9 lbs/min (5.4 kg/min)3.5
16.5 lbs/min (7.5 kg/min)3.9
22.5 lbs/min (10.2 kg/min)4.3
29.1 lbs/min (13.2 kg/min)4.7
Maximum5.0

MASS AIRFLOW SENSOR OUTPUT VOLTAGE

Condition(1) Volts
Primary HO2S
Lean4.7
Rich0.2
Secondary HO2S
Lean0.9
Rich0.1
(1) Voltage should pulse between values. Voltage values are approximate.
(1)Voltage should pulse between values. Voltage values are approximate.

OXYGEN SENSOR VOLTAGE

Measured Between Terminals(1) Ohms
3 & 45.7
(1) At 68°F (20°C).
(1)At 68°F (20°C).

OXYGEN SENSOR HEATER RESISTANCE

PositionVolts
Idle0.6
Maximum Throttle4.5

THROTTLE POSITION SENSOR VOLTAGE