Removal & Installation
- Disconnect negative battery cable. Remove viscous fan. Rotate accessory drive belt tensioner center bolt clockwise and remove accessory drive belt.
- Remove 2 generator mounting bolts and remove generator from mounting bracket. Remove terminal cover (if equipped) and remove leads from generator terminals. Remove generator.