Home/Kia/Rio/Kia Rio II рестайлинг (2009-2011)/Repair manual/A/c Compressor/Air Conditioning System: Removal & Installation
Contents Section: A/c Compressor All sections

Air Conditioning System: Removal & Installation Kia Rio II рестайлинг

A/c Compressor 2 illustrations ~231 words

REPLACEMENT OF COMPONENT PARTS

When replacing the system component parts, supply the following amount of oil to the component parts to be installed.

Component parts to be installedAmount of Oil
Evaporator50 cc (1.70 fl.oz)
Condenser30 cc (1.02 fl.oz)
Receiver/dryer30 cc (1.02 fl.oz)
Refrigerant line (One piece)10 cc (0.34 fl.oz)

OIL SPECIFICATION FOR INSTALLED PARTS

For compressor replacement, subtract the volume of oil drained from the removed compressor from the specified volume, and drain the calculated volume of oil from the new compressor

The specified volume - volume of removed compressor = volume to drain from the new compressor.

Note. Even if no oil is drained from the removed compressor, don't drain more than 50cc from new compressor.

Scheme 25

Scheme 25: COMPONENT LOCATION

REPLACEMENT

  1. Discharge refrigerant from refrigeration system (Refer to «SYSTEM CHARGING»(ref-378984-S08935915382010113000000) ).
  2. Replace faulty tube or hose. CAUTION: Cap the open fittings immediately to keep moisture or dirt out of the system.
  3. Tighten joint of bolt or nut to specified torque. CAUTION: Connections should not be torqued tighter than the specified torque. TORQUE SPECIFICATIONS Part tightened N.m Kgf.m lbf.ft Condenser x Discharge hose 8 ~ 12 0.8~1.2 5.8 ~ 8.7 Condenser x Liquid tube Compressor x Discharge hose Compressor x Suction hose Expansion valve x Evaporator
  4. Evacuate air in refrigeration system and charge system with refrigerant (Refer to «REFRIGERANT LEAK TEST»(ref-378984-S09959661602010113000000) ). Specified amount : 500 ± 25g
  5. Inspect for leakage of refrigerant. Using a gas leak detector, check for leakage of refrigerant (Refer to «SYSTEM CHARGING»(ref-378984-S08935915382010113000000) ).
  6. Inspect A/C operation.

Scheme 26

Scheme 26: COMPONENT LOCATION