Contents Section: Automatic HVAC System All sections

Air Conditioning: Other Jaguar XKR II рестайлинг

A/C COMPRESSOR

Item NumberDescription
1Pressure relief valve
2Outlet port
3Inlet port
4Solenoid valve
5Electrical connector
6Pulley

The A/C compressor circulates refrigerant around the system by compressing low pressure, low temperature vapor from the evaporator and discharging the resultant high pressure, high temperature vapor to the condenser.

The A/C compressor is a permanently engaged variable displacement unit which is driven by the engine accessory drive belt. To protect the system from excessive pressure, a pressure relief valve is installed in the outlet side of the A/C compressor. The pressure relief valve vents excess pressure into the engine compartment.

CONDENSER

Item NumberDescription
1Right Hand (RH) end tank
2Condenser core
3Left Hand (LH) end tank
4Mounting brackets (4 off)
5Low pressure line connector block
6High pressure line connector block
7Receiver drier outlet pipe
8Receiver drier inlet pipe
9Receiver drier

The condenser transfers heat from the refrigerant to the surrounding air to convert the high pressure vapor from the compressor into a liquid. The condenser is installed immediately in front of the radiator. Two brackets on each end tank attach the condenser to the end tanks of the radiator.

The condenser is classified as a sub-cooling condenser and consists of a fin and tube heat exchanger core installed between 2 end tanks. Divisions in the end tanks separate the heat exchanger into a 4 pass upper (condenser) section and a 2 pass lower (sub-cooler) section.

The LH end tank provides the connections to the high pressure line from the A/C compressor and the low pressure line to the evaporator.

The RH end tank provides the connections to the receiver drier.

RECEIVER DRIER

The receiver drier is mounted on the condenser RH end tank and removes solid impurities and moisture from the refrigerant. It also provides a reservoir for liquid refrigerant to accommodate changes of heat load at the evaporator.

Note. The receiver drier is part of the condenser assembly and is not serviceable separately.

Refrigerant entering the receiver drier passes through a filter and a desiccant pack, then collects in the base of the unit before flowing through the outlet pipe back to the condenser.

REFRIGERANT PRESSURE SENSOR

The refrigerant pressure sensor is located in the high pressure/temperature refrigerant line between the condenser and the thermostatic expansion valve. Refer to Control Components information.

THERMOSTATIC EXPANSION VALVE

Item NumberDescription
1Metering valve
2Housing
3Diaphragm
4Temperature sensor
5Outlet passage from evaporator
6Inlet passage to evaporator

The thermostatic expansion valve meters the flow of refrigerant into the evaporator, to match the refrigerant flow with the heat load of the air passing through the evaporator.

The thermostatic expansion valve is a block type valve located behind the heater assembly, and attached to the inlet and outlet ports of the evaporator. The thermostatic expansion valve consists of an aluminum housing containing inlet and outlet passages. A ball and spring metering valve is installed in the inlet passage and a temperature sensor is installed in the outlet passage. The temperature sensor consists of a temperature sensitive tube connected to a diaphragm. The bottom end of the temperature sensitive tube acts on the ball of the metering valve. Pressure on top of the diaphragm is controlled by the evaporator outlet temperature conducted through the temperature sensitive tube. The bottom of the diaphragm senses evaporator outlet pressure.

Liquid refrigerant flows through the metering valve into the evaporator. The restriction across the metering valve reduces the pressure and temperature of the refrigerant. The restriction also changes the liquid stream of refrigerant into a fine spray, to improve the evaporation process. As the refrigerant passes through the evaporator, it absorbs heat from the air flowing through the evaporator. The increase in temperature causes the refrigerant to vaporize and increase in pressure.

The temperature and pressure of the refrigerant leaving the evaporator acts on the diaphragm and temperature sensitive tube, which regulate the metering valve opening and so control the volume of refrigerant flowing through the evaporator. The warmer the air flowing through the evaporator, the more heat available to evaporate refrigerant and thus the greater volume of refrigerant allowed through the metering valve.

EVAPORATOR

The evaporator is installed in the heater assembly, between the blower and the heater matrix, to absorb heat from the exterior or recirculated air. Low pressure, low temperature refrigerant changes from liquid to vapor in the evaporator, absorbing large quantities of heat as it changes state.

Most of the moisture in the air passing through the evaporator condenses into water, which drains out of the vehicle by passing through a drain tube to the underside of the vehicle.

REFRIGERANT LINES

To maintain similar flow velocities around the A/C system, the diameter of the refrigerant lines varies to suit the 2 pressure/temperature regimes. Larger diameter pipes are installed in the low pressure/temperature regime and smaller diameter pipes are installed in the high pressure/temperature regime.

Low and high pressure charging connections are incorporated into the refrigerant lines for system servicing.

CONTROL DIAGRAM

Item NumberDescription
1Evaporator
2Thermostatic expansion valve
3High pressure servicing connection
4Refrigerant pressure sensor
5Engine cooling fan
6Condenser
7Receiver/Drier
8Variable displacement A/C compressor
9Low pressure servicing connection
10Blower

Note. A = Refrigerant liquid; B = Refrigerant vapor; C = Air flow