INTRODUCTION
Sensor operating range information is supplied so that it can be determined if a sensor is out of calibration. A sensor that is out of calibration may not set a trouble code, however, it will cause driveability problems.
| BARO Pressure - In. Hg | Volts |
| 0 | 2.8-3.0 |
| 5 | 2.3-2.5 |
| 10 | 1.8-2.0 |
| 15 | 1.3-1.5 |
| 20 | .8-1.0 |
| 25 | .3-.5 |
| (1) Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS . |
| (1) | Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS . |
ATMOSPHERIC PRESSURE (PA) SENSOR VOLTAGE TEST (1)
| Temperature - °F (°C) | Resistance (Ohms) |
| 4 (-20) | 15,000-18,000 |
| 68 (20) | 1,000-4,000 |
| 176 (80) | 200-400 |
| (1) Measure resistance across sensor terminals. |
| (1) | Measure resistance across sensor terminals. |
COOLANT TEMPERATURE (TW) SENSOR RESISTANCE TEST (1)
| Temperature - °F (°C) | Resistance (Ohms) |
| 4 (-20) | 15,000-18,000 |
| 68 (20) | 1,000-4,000 |
| 176 (80) | 200-400 |
| (1) Measure resistance across sensor terminals. |
| (1) | Measure resistance across sensor terminals. |
INTAKE AIR TEMPERATURE (TA) SENSOR RESISTANCE TEST (1)
| Vacuum Applied - In. Hg. | Volts |
| 0 | 2.8-3.0 |
| 5 | 2.3-2.5 |
| 10 | 1.8-2.0 |
| 15 | 1.3-1.5 |
| 20 | .8-1.0 |
| 25 | .3-.5 |
| (1) Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS . |
MAP SENSOR VOLTAGE TEST (1)
| Position | Volts (Approx.) |
| Accord & Prelude |
| Fully Closed | 1.2 |
| Fully Open | 4.0 |
| Civic & CRX |
| Fully Closed | 1.0 |
| Fully Open | 4.5 |
| (1) Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS . Voltage should increase smoothly as vacuum is applied. |
| (1) | Measure voltage at appropriate ECU terminals. See WIRING DIAGRAMS . Voltage should increase smoothly as vacuum is applied. |
EGR LIFT SENSOR VOLTAGE TEST (1)
| Condition | Volts |
| Lean | Less Than 0.4 |
| Rich | Greater Than 0.6 |
| (1) Measure voltage between ground and O2 sensor terminal using a high-impedance DVOM. |
| (1) | Measure voltage between ground and O2 sensor terminal using a high-impedance DVOM. |
OXYGEN SENSOR VOLTAGE TEST (1)