Contents Section: Body Electrical All sections

Power Outlets: Other GMC Acadia I рестайлинг

Body Electrical ~404 words

Intermittent

Electrical connections or wiring may be the cause of intermittent conditions. Refer to Testing for Intermittent Conditions and Poor Connections

Reference Information

Schematic Reference

Cigar Lighter/Power Outlet Schematics

Connector End View Reference

COMPONENT CONNECTOR END VIEWS - INDEX

Description and Operation

Power Outlets Description and Operation

Electrical Information Reference

  1. «Circuit Testing»(ref-610066-S15766520632014042100000)
  2. «Connector Repairs»(ref-610066-S09830970062014042100000)
  3. «Testing for Intermittent Conditions and Poor Connections»(ref-610066-S03531120952014042100000)
  4. «Wiring Repairs»(ref-610066-S23061455012014042100000)

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

Cigar Lighter Receptacle or 12-Volt Accessory Power Receptacle Replacement

Schematic Reference

Cigar Lighter/Power Outlet Schematics

Connector End View Reference

COMPONENT CONNECTOR END VIEWS - INDEX

Description and Operation

Power Outlets Description and Operation

Electrical Information Reference

  1. «Circuit Testing»(ref-610066-S15766520632014042100000)
  2. «Connector Repairs»(ref-610066-S09830970062014042100000)
  3. «Testing for Intermittent Conditions and Poor Connections»(ref-610066-S03531120952014042100000)
  4. «Wiring Repairs»(ref-610066-S23061455012014042100000)

Circuit/System Verification

  1. Ignition ON.
  2. Connect an AC powered device to the Accessory Power Receptacle - 110V AC.
  3. Verify the Accessory DC/AC Power Control Module is turned ON and the device works as expected. If the device is not powered Refer to «Circuit/System Testing»(ref-610117-S40577636742014042100000) . If the device is powered
  4. All OK.

Perform the Diagnostic Repair Verification after completing the repair.

110 Volt Power Outlet Receptacle Isolation Fault Protection

The accessory DC/AC power inverter module contains a ground fault circuit interrupter (GFCI). GFCI monitors the 110 V circuit for a short to vehicle chassis ground. If a 110 V AC short to ground is detected, the accessory DC/AC power inverter module will turn OFF. The module remains OFF, until the AC powered device is unplugged from the outlet and then plugged into the outlet after a 3 second delay.

110 Volt Power Outlet Receptacle Overload Shutdown

The accessory DC/AC power inverter module will turn OFF if the current in the 110 V circuit is greater than 3.8 A for 1 second or 2.5 A for 10 seconds. The module will turn ON again, when the AC powered device is unplugged from the outlet and then plugged into the outlet after a 3 second delay.

110 Volt Power Outlet Receptacle Internal Shutdown

The accessory DC/AC power inverter module will turn OFF if the B+ supply voltage is greater than 16.5 V or less than 11 V. The module will also turn OFF if the device temperature is greater than 85°C (185°F). The module will turn ON again, after the shutdown condition is corrected and the AC powered device is unplugged from the outlet and then plugged into the outlet.