Removal and Installation
Note. The RH and LH cooling fans can be serviced individually. The LH cooling fan is shown, the RH is similar.
Scheme 19
Scheme 20
Scheme 21
- Remove the distribution box and position aside.
- Disconnect the fan electrical connector and detach the retainer.
- Remove the bolt and the electrical cooling fan.
- To install, reverse the removal procedure.
Scheme 22
Scheme 23
Scheme 24
- Drain the coolant below the degas bottle. For additional information, refer to «COOLING SYSTEM DRAINING, FILLING AND BLEEDING»(ref-212100-S06677154962005122300000) .
- Disconnect the upper hoses.
- Disconnect the lower hose.
- Remove the bolt and the nut, remove the degas bottle.
- To install, reverse the removal procedure.