REMOVAL AND INSTALLATION
- Remove the 2 nuts, the bolt and the generator air inlet duct. To install, tighten to 6 Nm (53 lb-in).
- Disconnect the 4 ignition coil-on-plug electrical connectors.
- Remove the 4 bolts and the ignition coil-on-plugs. To install, tighten to 10 Nm (89 lb-in).
- To install, reverse the removal procedure. Apply a small amount of dielectric grease to the inside of the ignition coil-on-plug boots before attaching to the spark plugs.
REMOVAL
- Remove the 2 nuts, the bolt and the generator air inlet duct.
- Disconnect the 4 ignition coil-on-plug electrical connectors.
- Remove the 4 bolts and the ignition coil-on-plugs.
- Remove the 4 spark plugs.
INSTALLATION
- Inspect the spark plugs. Item Part Number Description 1 - Deposits bridging spark plug gap 2 - Wet black deposits (oil fouling) 3 - Dry black deposits (carbon fouling) 4 - Normal spark plug 5 - Pre-ignition 6 - Overheating 7 - Fused spot deposits
- Adjust the spark plug gap as necessary.
- Install the spark plugs. Tighten to 12 Nm (9 lb-ft).
- Install the 4 ignition coils and bolts. Tighten to 10 Nm (89 lb-in).
- Connect the 4 ignition coil electrical connectors.
- Install the generator air inlet duct and the 2 nuts and the bolt. Tighten to 6 Nm (53 lb-in).