Normal Operation and Fault Conditions
Refer to: Starting System - System Operation and Component Description ( Starting System - System Operation and Component Description .
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| P0833:23 | Clutch Pedal Switch B Circuit: Signal Stuck Low | This DTC sets when the BCM detects a short to ground on the clutch bottom of travel circuit during an on-demand self test. |
DTC FAULT TRIGGER CONDITIONS
Correct starter operation relies on correct mounting of the starter to the engine, alignment of the starter ring gear to the flexplate and correct functioning of the starter assembly (internal gears, bearings).
Refer to: Starting System - Overview ( Starting System - Overview ).
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| P0615 | Starter Relay Circuit | This DTC is set when the PCM detects a fault in the starter relay control circuit(s). |
DTC FAULT TRIGGER CONDITIONS
When the ignition switch - push button start has been pressed, the PCM receives a voltage signal on the crank detect circuit. When the required inputs have been received, the PCM supplies voltage and ground to the starter relay coil.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| P2535 | Ignition Switch Run/Start Position Circuit High | This DTC is set when the PCM detects a short to voltage on the crank detect circuit while engine is running. |
DTC FAULT TRIGGER CONDITIONS
The wake-up control circuit wakes up the PCM prior to engine cranking. The PCM needs to wake up prior to a crank request so it has time to go through its initialization. The wake-up control circuit is controlled by the BCM. The BCM activates the wake-up control circuit when: the driver door is opened. a key is inserted into the ignition. or when the ignition is in the ON or START position.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B10E5:11 | PCM Wake-up Signal: Circuit Short to Ground | Set by the BCM when a short to ground is detected on the wake-up control circuit. |
| B10E5:15 | PCM Wake-up Signal: Circuit Short to Battery or Open | Set by the BCM when a short to voltage or an open is detected on the wake-up control circuit. |
DTC FAULT TRIGGER CONDITIONS