Home/Ford/Flex/Ford Flex I (2008-2013)/Repair manual/Manual HVAC System/HVAC - Climate Control System: Specifications
Contents Wiring diagrams Section: Manual HVAC System All sections

HVAC - Climate Control System: Specifications Ford Flex I

MATERIAL SPECIFICATIONS

ItemSpecificationFill Capacity
MERCON® V Automatic Transmission Fluid XT-5-QM (or XT-5-QMC) (US); CXT-5-LM12 (Canada)MERCON® V
PAG Refrigerant Compressor Oil (R-134a Systems) YN-12-DWSH-M1C231-B281 ml (9.5 fl oz)
R-134a Refrigerant YN-19 (US); CYN-16-P or CYN-16-R (Canada)WSH-M17B19-A1.02 kg (36 oz) (2.25 lb)

MATERIAL SPECIFICATIONS

GENERAL SPECIFICATIONS

ItemSpecification
Magnetic Clutch
Air gap between pulley and clutch plate0.35-0.65 mm (0.014-0.026 in)

GENERAL SPECIFICATIONS

TORQUE SPECIFICATIONS

DescriptionNm
A/C compressor bolts25
A/C compressor fitting nuts (suction and discharge)15
A/C compressor mounting stud9
A/C compressor nut25
A/C compressor pressure relief valve10
A/C clutch disc and hub bolt14
Auxiliary evaporator inlet line fitting nut15
Auxiliary evaporator outlet line fitting nut15
Condenser bolts6
Condenser fitting nuts (inlet and outlet)15
Cross-vehicle beam nuts30
Evaporator inlet line fitting bracket bolt15
Evaporator inlet line fitting nut15
Evaporator outlet line fitting nut15
Front bumper cover bolts6
Heater core and evaporator core housing bolts7
High-pressure Schrader-type valve2.5
High-pressure service gauge port valve cap0.8
Low-pressure Schrader-type valve1.8
Low-pressure service gauge port valve cap0.8
Receiver/drier bolts9
Receiver/drier outlet fitting nut15
Thermostatic Expansion Valve (TXV) bolts8
TXV fitting nut8
TXV fitting stud8
TXV manifold and tube bracket bolt15
TXV manifold and tube clamp bracket bolt9

TORQUE SPECIFICATIONS