STARTER MOTOR SPECIFICATIONS
| Application | Specification | |
|---|---|---|
| Cranking Speed (Normal Load) | 140-220 RPM | |
| Current Draw | ||
| Normal Load | 130-190 Amps | |
| Maximum Load | 800 Amps | |
| No Load | 60-80 Amps | |
| Starter Circuit Voltage Drop (MAX) | .5 Volt | |
STARTER MOTOR SPECIFICATIONS
TORQUE SPECIFICATIONS
| Application | Ft. Lbs. (N.m) |
|---|---|
| Starter Motor Ground Cable Nut | 13-17 (18-23) |
| Starter Motor Mounting Bolts | 16-20 (22-27) |
| INCH Lbs. (N.m) | |
| Digital Transmission Range Sensor Bolts | 71-89 (8-10) |
| Solenoid "B" Terminal Nut | 89-120 (10-14) |
| Solenoid "S" Terminal Nut | 53 (6) |
| Solenoid Relay Mounting Bolts | 61-79 (7-9) |
TORQUE SPECIFICATIONS