BELT ADJUSTMENT
Note. For belt routing on models not covered in this article, information was not available. See underhood label for proper belt routing.
Belts should be adjusted to proper tension using belt tension gauge. See BELT ADJUSTMENT SPECIFICATIONS table. Some models may be equipped with an automatic belt tensioner. Ensure serpentine belts are routed properly. (Scheme 2)- (Scheme 9).
| Application | New Belt Lbs. (kg) | (1) Used Belt Lbs. (kg) |
| Dakota |
| 2.5L |
| A/C | 160 (73) | 80 (36) |
| Generator & Water Pump | 160 (73) | 80 (36) |
| Power Steering | 120 (54) | 80 (36) |
| 3.9L & 5.2L | (2) | (2) |
| Caravan & Voyager |
| 2.4L |
| A/C & Generator |
| 1996 | 150 (68) | 80 (36) |
| 1997 | 190 (86) | 115 (52) |
| Power Steering |
| 1996 | 130 (59) | 80 (36) |
| 1997 | 140 (64) | 90 (41) |
| 3.0L |
| A/C |
| 1996 | 125 (57) | 80 (36) |
| 1997 | 150 (68) | 80 (36) |
| Generator & P/S | (2) | (2) |
| 3.3L & 3.8L | (2) | (2) |
| Town & Country |
| 3.3L & 3.8L | (2) | (2) |
| Ram Pickup & Ram Van/Wagon |
| All Engines | (2) | (2) |
| (1) Belt is considered used after 15 minutes of service. (2) Automatic belt tensioner is used. Belt tension adjustment is not required. |
| (1) | Belt is considered used after 15 minutes of service. |
| (2) | Automatic belt tensioner is used. Belt tension adjustment is not required. |
BELT ADJUSTMENT SPECIFICATIONS
Scheme 1
Scheme 2
Scheme 3
Scheme 4
Scheme 5
Scheme 6
Scheme 7
Scheme 8
Scheme 9
| Application | Specification |
| Coolant Replacement Interval | 45,000 Miles Or 36 Months |
| Coolant Capacity (1) |
| FWD Vans |
| 2.4L | (2) 11.2 Qts. (10.6L) |
| 3.0L | (2) 13.0 Qts. (12.3L) |
| 3.3L & 3.8L | (2) 13.2 Qts. (12.5L) |
| Dakota |
| 2.5L | 9.8 Qts. (9.3L) |
| 3.9L | 14.0 Qts. (13.2L) |
| 5.2L | 14.3 Qts. (13.5L) |
| Ram Pickup |
| 3.9L, 5.2L & 5.9L (Gas) | 20.0 Qts. (18.9L) |
| 5.9L (Diesel) |
| 1996 | 28.0 Qts. (26.5L) |
| 1997 | 24.0 Qts. (22.7L) |
| 8.0L | 26.0 Qts. (24.6L) |
| Ram Van/Wagon |
| 3.9L | 14.5 Qts. (13.7L) |
| 5.2L | 16.5 Qts. (15.6L) |
| 5.9L |
| With Rear Heater | 16.0 Qts. (15.1L) |
| Without Rear Heater | 15.0 Qts. (14.2L) |
| Pressure Cap | 16 psi |
| Thermostat |
| Starts To Open | 195°F (91°C) |
| Fully Opens | 216°F (102°C) |
| (1) Capacities listed are approximate. (2) Capacity includes heater and coolant recovery tank. Add 2 qts. (1.9L) for models equipped with rear heater. |
| (1) | Capacities listed are approximate. |
| (2) | Capacity includes heater and coolant recovery tank. Add 2 qts. (1.9L) for models equipped with rear heater. |
COOLING SYSTEM SPECIFICATIONS