Contents Wiring diagrams Section: Engine All sections

Data: cooling system Citroen Jumpy I

Data

data
system capacity9 litre(s)
system protection-35 deg. C
liquid usedPROCOR 3000
intervalevery 2 year(s)
chamber separated from the radiator
cap pressure1 bar(s)
colour identificationorange
coolant level sensoryes
data
radiator harnesscopper
surface area30 dm2
temperature
start of opening83 deg. C
end of opening95 deg. C
air conditioningwithout air conditioning
number of fans21
power (climate 37 deg. C)180W + 250W250W
power (climate 45 deg. C)
post ventilationno
cutting in/out of fan (stage 1)90/8792/89
cutting in/out of fan (stage 2)101/9897/94
air conditioningwithout air conditioning
number of fans2
power (climate 37 deg. C)180W + 450W180W + 250W
power (climate 45 deg. C)
post ventilationno
cutting in/out of fan (stage 1)90/8792/89
cutting in/out of fan (stage 2)101/9897/94

Temperature sensor positioning

The tightening torque of the sensors and caps on the coolant housing outlet is 1,8 m.daN

Water outlet housing

  • A = cylinder head side
  • B = coolant outlet
reference(A)(B)(C)on the radiator
sensorthermal switchcaptemperature sensorthermal switch
informationlogo + warning (110 deg. C)--fan
connector colourbluegreenblue
ring colourgreygreymauve
reference(A)(B)(C)
sensorthermal switchcoolant thermistortemperature sensor
informationlogocoolant temperature unit (BITRON)-
connector colourbluebrowngreen
ring colour--grey
reference(A)(B)(C)on the radiator
sensorthermal switchcapthermal switch 60 deg. Cthermal switch
informationlogo + warning (110 deg. C)--fan
connector colourbluegreenblue
ring colourgreymauvemauve
reference(A)(B)(C)
sensorthermal switchcoolant thermistorthermal switch 60 deg. C
informationlogocoolant temperature unit (BITRON)-
connector colourbluebrowngreen
ring colour--mauve